Advancing Well Integrity: Petronas’ First Application of Time-Activated Sealant Technology

Abstract Background and Scope Within aging brownfields, maintaining the integrity of wellheads and control lines presents a prevalent challenge. This issue becomes particularly acute in wells with high production rates, especially those containing elevated levels of CO2 and sand, requiring urgent rectification measures. Whether stemming from leaks in the neck seal, tubing hanger MTM, elastomers, or control lines, the leak rates can vary significantly, ranging from as large as 1000 ml/min at 3000 psi to as small as 50 ml/min at 500 psi. Traditionally, plastic packing and pressure-activated sealants have been employed to address these integrity concerns. However, these solutions have frequently encountered recurrent failures within six months of application. For instance, in the case of Well A, which experienced a control line leak and was treated with pressure-activated sealant, the solution proved ineffective, resulting in a failure within three months. Subsequent diagnostics revealed a leak rate of 2000 ml/min at 150 psi, indicating the inadequacy of the applied solution. Given the urgency and magnitude of the leak issue, the proposed solution involves the application of a time-activated sealant to address the leak rate of 2000 ml/min. Process and Selection Method The time-activated sealant is a specialized polymer sealant engineered to effectively seal various types of leaks, including flange leaks, neck seal leaks, and void pack-off leaks in tubing and casing hanger elastomeric seals. Its primary function is to prevent continuous communication and pressure transmission from the annulus. Notably, it does not form bonds with metal surfaces, facilitating easy dismantlement during future wellhead operations. This sealant boasts exceptional properties, including extreme high compressive strengths exceeding four times that of advanced cement slurries. Additionally, it exhibits ultra-high shear bond strengths exceeding 1,650 psi and generates an exothermic reaction upon curing. Importantly, it is not soluble in water or oil. Its curing process occurs at low temperatures and utilizes a total liquid system, enabling it to penetrate small channels and micro-annuli effectively. Moreover, the sealant offers controlled pump times and set times, utilizing a crosslink design tailored to specific well specifications and downhole conditions. This comprehensive set of attributes makes it a highly versatile and reliable solution for sealing applications in oil and gas wells. Result Performed squeeze and wait on crosslinking (WOC) process by injecting fresh water into the control line at maximum pumping pressure and ensuring a pump rate of 2000 ml/min. Mixed the sealant and commenced pumping it into the control line, purging all excess sealant until pressure peaked. Followed by pumping 200 ml of fresh water, followed by 400 ml of sealant until pressure reached maximum pumping pressure, then waited for 48 hours. Conducted a pressure test up to 80% of the Christmas tree rating and observed no pressure drop, confirming the restoration of integrity. For void area leak Application, eight times injection into void were performed. Major void area leak at 2000ml/min is successfully shut off with no injectivity at 2700 psi and pressure drop reduced from 3 to 1.6 psi/min. However, with negative pressure test on PCP while bleeding off the void area indicates that the void area leak is not cured. Conclusion The time-activated sealant (TAS) utilized for Control Line (CL) Abandonment is deemed successful. However, in void area application, it has significantly reduced the leak rate but did not fully isolate pressure from PCP to Void Area.

Authors

Institutions

Publication Details

Published
2024-11-04
DOI
https://doi.org/10.2118/222358-ms
Primary Topic
Drilling and Well Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing Well Integrity: Petronas’ First Application of Time-Activated Sealant Technology

Youngbin Shan, M. I. Abd Jalil, Xiaohu Jin, S. A Syed Mohd Shahril et al.
Drilling and Well Engineering
article

Advancing Well Integrity: Petronas’ First Application of Time-Activated Sealant Technology

Youngbin Shan, M. I. Abd Jalil, Xiaohu Jin, S. A Syed Mohd Shahril, P.K. Nair, Chandar Chandar
article en

Abstract

Abstract Background and Scope Within aging brownfields, maintaining the integrity of wellheads and control lines presents a prevalent challenge. This issue becomes particularly acute in wells with high production rates, especially those containing elevated levels of CO2 and sand, requiring urgent rectification measures. Whether stemming from leaks in the neck seal, tubing hanger MTM, elastomers, or control lines, the leak rates can vary significantly, ranging from as large as 1000 ml/min at 3000 psi to as small as 50 ml/min at 500 psi. Traditionally, plastic packing and pressure-activated sealants have been employed to address these integrity concerns. However, these solutions have frequently encountered recurrent failures within six months of application. For instance, in the case of Well A, which experienced a control line leak and was treated with pressure-activated sealant, the solution proved ineffective, resulting in a failure within three months. Subsequent diagnostics revealed a leak rate of 2000 ml/min at 150 psi, indicating the inadequacy of the applied solution. Given the urgency and magnitude of the leak issue, the proposed solution involves the application of a time-activated sealant to address the leak rate of 2000 ml/min. Process and Selection Method The time-activated sealant is a specialized polymer sealant engineered to effectively seal various types of leaks, including flange leaks, neck seal leaks, and void pack-off leaks in tubing and casing hanger elastomeric seals. Its primary function is to prevent continuous communication and pressure transmission from the annulus. Notably, it does not form bonds with metal surfaces, facilitating easy dismantlement during future wellhead operations. This sealant boasts exceptional properties, including extreme high compressive strengths exceeding four times that of advanced cement slurries. Additionally, it exhibits ultra-high shear bond strengths exceeding 1,650 psi and generates an exothermic reaction upon curing. Importantly, it is not soluble in water or oil. Its curing process occurs at low temperatures and utilizes a total liquid system, enabling it to penetrate small channels and micro-annuli effectively. Moreover, the sealant offers controlled pump times and set times, utilizing a crosslink design tailored to specific well specifications and downhole conditions. This comprehensive set of attributes makes it a highly versatile and reliable solution for sealing applications in oil and gas wells. Result Performed squeeze and wait on crosslinking (WOC) process by injecting fresh water into the control line at maximum pumping pressure and ensuring a pump rate of 2000 ml/min. Mixed the sealant and commenced pumping it into the control line, purging all excess sealant until pressure peaked. Followed by pumping 200 ml of fresh water, followed by 400 ml of sealant until pressure reached maximum pumping pressure, then waited for 48 hours. Conducted a pressure test up to 80% of the Christmas tree rating and observed no pressure drop, confirming the restoration of integrity. For void area leak Application, eight times injection into void were performed. Major void area leak at 2000ml/min is successfully shut off with no injectivity at 2700 psi and pressure drop reduced from 3 to 1.6 psi/min. However, with negative pressure test on PCP while bleeding off the void area indicates that the void area leak is not cured. Conclusion The time-activated sealant (TAS) utilized for Control Line (CL) Abandonment is deemed successful. However, in void area application, it has significantly reduced the leak rate but did not fully isolate pressure from PCP to Void Area.

Petronas (Malaysia) (MY), Everbright International (China) (CN)
Openalex Percentile: Top 74%
Drilling and Well Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.