Monitoring and Control of Irradiation with Carbon Ions During Radiobiological Experiments at the RBS Experimental Set-Up

The RBS experimental set-up has been working in every accelerator session of the U-70 accelerator complex since 2015. The main users of the set-up are radiobiologists and physicians. The direction of research is radiobiological experiments with extracted beams of accelerated carbon ions and preclinical studies aimed at the development of domestic methods of ion therapy. The requirements for irradiation of samples with carbon ions are very high: irradiation uniformity is no worse than 95%, positioning accuracy is no worse than 0.1 mm, dose delivery accuracy is no worse than ±2.5%. The article describes the instruments and devices that are used to support radiobiological experiments at the RBS installation: a plane-parallel ionization chamber, a mosaic ionization chamber, a water phantom with a 3D movement system, a 6-axis table, a degrader, a laser positioning system, clinical dosimeters. Programs for working with this equipment and archiving the data obtained are described.

Authors

Institutions

Publication Details

Journal
Siberian Journal of Physics
Published
2024-10-31
DOI
https://doi.org/10.25205/2541-9447-2024-19-3-25-37
Citations
1
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring and Control of Irradiation with Carbon Ions During Radiobiological Experiments at the RBS Experimental Set-Up

М. K. Polkovnikov, V. A. Pikalov, V. Kovaltsov, S. V. Makonin et al.
1 citations
Siberian Journal of Physics
Radiation Effects and Dosimetry
0.35
article

Monitoring and Control of Irradiation with Carbon Ions During Radiobiological Experiments at the RBS Experimental Set-Up

М. K. Polkovnikov, V. A. Pikalov, V. Kovaltsov, S. V. Makonin, А. В. Кошелев, A. V. Lutchev, D. A. Vasiliev
article en
1 citations

Abstract

The RBS experimental set-up has been working in every accelerator session of the U-70 accelerator complex since 2015. The main users of the set-up are radiobiologists and physicians. The direction of research is radiobiological experiments with extracted beams of accelerated carbon ions and preclinical studies aimed at the development of domestic methods of ion therapy. The requirements for irradiation of samples with carbon ions are very high: irradiation uniformity is no worse than 95%, positioning accuracy is no worse than 0.1 mm, dose delivery accuracy is no worse than ±2.5%. The article describes the instruments and devices that are used to support radiobiological experiments at the RBS installation: a plane-parallel ionization chamber, a mosaic ionization chamber, a water phantom with a 3D movement system, a 6-axis table, a degrader, a laser positioning system, clinical dosimeters. Programs for working with this equipment and archiving the data obtained are described.

Siberian Journal of PhysicsVol. 19(3)
Kurchatov Institute (RU)
Openalex Percentile: Top 35%
Radiation Effects and Dosimetry
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.