Process efficiency assessment of turbidity removal from tigris river using microfiltration membranes

The current study aims to use microfiltration membrane units instead of using traditional treatment methods (flocculation and coagulation) to enhance water treatment efficiency and lower operational and fixed costs. Specifically, it explores using a polypropylene membrane with a pore size of 1 µm and a ceramic membrane with a pore size of 0.5 µm to remove turbidity, total suspended solid TSS, and Escherichia coli bacteria from the Tigris River water within Baghdad. An experimental study compared the removal efficiency of real and simulated Tigris River water with different turbidity for polypropylene and ceramic membranes. Operational parameters such as initial turbidity concentration, temperature, flow rate, and membrane fouling were studied as a function of time. Also, two operating methods, dead-end, and crossflow, were discussed regarding the removal efficiency of suspended solids, turbidity, and Escherichia coli bacteria 65 %, 91 %, and 99 %, respectively, for the polypropylene membrane. And 75 %, 97 %, and 100 % for the ceramic membrane. The results of the current study indicate that ceramic membranes are the most susceptible to contamination by fouling, but at the same time, they are the most resistant and have the highest rate of removal efficiency than the polypropylene membrane. In addition, the crosse flow operation is better than the dead-end operation and is also considered a way to reduce the fouling that occurs in the membrane filtration. Microfiltration in general can achieve economic profit and minimal environmental impact, and ceramic microfiltration membranes in particular can achieve high-quality water. • Ceramic membranes is very effective in eliminating turbidity and bacteria removal with an efficiency of 99.5 %. • PP has less turbidity and bacteria removal. • PP is more resistant to fouling and less susceptible to clogging.

Authors

Institutions

Publication Details

Journal
Desalination and Water Treatment
Published
2024-10-01
DOI
https://doi.org/10.1016/j.dwt.2024.100879
Citations
3
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.60
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Process efficiency assessment of turbidity removal from tigris river using microfiltration membranes

Muayad Al-Shaeli, Ahmed Alalawi, Noor Jasim Al-Tamimi
3 citations
Desalination and Water Treatment
Membrane Separation Technologies
0.60
article

Process efficiency assessment of turbidity removal from tigris river using microfiltration membranes

Muayad Al-Shaeli, Ahmed Alalawi, Noor Jasim Al-Tamimi
article en
3 citations

Abstract

The current study aims to use microfiltration membrane units instead of using traditional treatment methods (flocculation and coagulation) to enhance water treatment efficiency and lower operational and fixed costs. Specifically, it explores using a polypropylene membrane with a pore size of 1 µm and a ceramic membrane with a pore size of 0.5 µm to remove turbidity, total suspended solid TSS, and Escherichia coli bacteria from the Tigris River water within Baghdad. An experimental study compared the removal efficiency of real and simulated Tigris River water with different turbidity for polypropylene and ceramic membranes. Operational parameters such as initial turbidity concentration, temperature, flow rate, and membrane fouling were studied as a function of time. Also, two operating methods, dead-end, and crossflow, were discussed regarding the removal efficiency of suspended solids, turbidity, and Escherichia coli bacteria 65 %, 91 %, and 99 %, respectively, for the polypropylene membrane. And 75 %, 97 %, and 100 % for the ceramic membrane. The results of the current study indicate that ceramic membranes are the most susceptible to contamination by fouling, but at the same time, they are the most resistant and have the highest rate of removal efficiency than the polypropylene membrane. In addition, the crosse flow operation is better than the dead-end operation and is also considered a way to reduce the fouling that occurs in the membrane filtration. Microfiltration in general can achieve economic profit and minimal environmental impact, and ceramic microfiltration membranes in particular can achieve high-quality water. • Ceramic membranes is very effective in eliminating turbidity and bacteria removal with an efficiency of 99.5 %. • PP has less turbidity and bacteria removal. • PP is more resistant to fouling and less susceptible to clogging.

Desalination and Water TreatmentVol. 320
University of Baghdad (IQ), University of Luxembourg (LU)
Clean water and sanitation
Openalex Percentile: Top 33%
Membrane Separation Technologies
0.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.