PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA

Background: This research on the performance testing of the Magnetic Resonance Imaging (MRI) machine was conducted using performance tests on three different parameters at Kasih Ibu Hospital Saba. This research aims to determine the performance of the MRI machine at Kasih Ibu Hospital Saba in Bali Province and establish baseline data for future testing. Method: This type of research is quantitative and uses a survey approach. The tools and materials used in this study are a 0.35 Tesla MRI machine, an ACR phantom, and a head coil. Data were collected by conducting nine MRI performance testing procedures using the ACR (2015) guidelines and then analyzed using international standards issued by ACR (2015). Result: In the visual checklist testing, all observed parameters were over 30 days and functioned well, For the Artifact Evaluation test, the author evaluated all scanned images and found no artifacts. The author analyzed the measurements from the first slice of T1W and T2W images for the Slice Thickness Accuracy test. The measurement results for the T1W image were 4.6mm, and for the T2W image, they were 5.57mm. The Slice Thickness Accuracy testing standard set by ACR in 2015 is 5mm ± 0.7mm. Therefore, based on the measurement results from the T1W and T2W images, the MRI machine at Kasih Ibu Saba Hospital meets the established international standards. Conclusion: Based on the results of the visual checklist test, the following results were obtained: all parameters on the visual checklist functioned well during the 30-day observation. Meanwhile, the two tests conducted with the phantom on the MRI machine at Kasih Ibu Hospital Saba the following results are: the artifact evaluation test and the slice thickness accuracy test met the international standards set by ACR in 2015.

Authors

Publication Details

Journal
Journal of Applied Health Management and Technology
Published
2024-10-31
DOI
https://doi.org/10.31983/jahmt.v6i2.11947
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA

I Made Lana Prasetya, I Wayan Ariec Sugiantara, Gusti Agung Putu Adhinta Purnama Dewi
Journal of Applied Health Management and Technology
Oil and Gas Production Techniques
article

PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA

I Made Lana Prasetya, I Wayan Ariec Sugiantara, Gusti Agung Putu Adhinta Purnama Dewi
article en

Abstract

Background: This research on the performance testing of the Magnetic Resonance Imaging (MRI) machine was conducted using performance tests on three different parameters at Kasih Ibu Hospital Saba. This research aims to determine the performance of the MRI machine at Kasih Ibu Hospital Saba in Bali Province and establish baseline data for future testing. Method: This type of research is quantitative and uses a survey approach. The tools and materials used in this study are a 0.35 Tesla MRI machine, an ACR phantom, and a head coil. Data were collected by conducting nine MRI performance testing procedures using the ACR (2015) guidelines and then analyzed using international standards issued by ACR (2015). Result: In the visual checklist testing, all observed parameters were over 30 days and functioned well, For the Artifact Evaluation test, the author evaluated all scanned images and found no artifacts. The author analyzed the measurements from the first slice of T1W and T2W images for the Slice Thickness Accuracy test. The measurement results for the T1W image were 4.6mm, and for the T2W image, they were 5.57mm. The Slice Thickness Accuracy testing standard set by ACR in 2015 is 5mm ± 0.7mm. Therefore, based on the measurement results from the T1W and T2W images, the MRI machine at Kasih Ibu Saba Hospital meets the established international standards. Conclusion: Based on the results of the visual checklist test, the following results were obtained: all parameters on the visual checklist functioned well during the 30-day observation. Meanwhile, the two tests conducted with the phantom on the MRI machine at Kasih Ibu Hospital Saba the following results are: the artifact evaluation test and the slice thickness accuracy test met the international standards set by ACR in 2015.

Journal of Applied Health Management and TechnologyVol. 6(2)
Partnerships for the goals
Openalex Percentile: Top 75%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA — I Made Lana Prasetya, I Wayan Ariec Sugiantara, et al. · Journal of Applied Health Management and Technology (2024) | TGRS Research Map | TGRS