Portable Detection of Copper Ion Using Personal Glucose Meter

A simple and sensitive method for Cu<sup>2+</sup> detection was developed using the Cu<sup>+</sup>-catalyzed alkyne-azide cycloaddition reaction, Fe<sub>3</sub>O<sub>4</sub> magnetic nanoparticles (MNPs) as the reaction platform, and a portable blood glucose meter (PGM) as the detection method. Gold nanoparticles (AuNPs) were labeled with glucose oxidase (GOx) and alkyne-functionalized, terminally thiolated ssDNA (C2). In the presence of Cu<sup>2+</sup> and ascorbate, the functionalized AuNPs were captured onto MNPs modified with azide-functionalized ssDNA (C1) via the Cu<sup>+</sup>-catalyzed alkyne-azide cycloaddition reaction. The GOx on the AuNPs' surface oxidized glucose (Glu) into gluconic acid and H<sub>2</sub>O<sub>2</sub>, reducing the Glu content in the reaction solution, which was quantitatively detected by the PGM. Under optimal conditions, the PGM response of the system showed a good linear relationship with the logarithm of Cu<sup>2+</sup> concentration in the range of 0.05 to 10.00 μmol/L, with a detection limit of 0.03 μmol/L (3σ). In actual tap water samples, the spiked recovery rate of Cu<sup>2+</sup> was between 92.30% and 113.33%, and the relative standard deviation was between 0.14% and 0.34%, meeting the detection requirements for Cu<sup>2+</sup> in real water samples.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-10-31
DOI
https://doi.org/10.3390/s24217002
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable Detection of Copper Ion Using Personal Glucose Meter

Haijun Chen, Anqi Huang, Bin Du, Wei Liu et al.
Sensors
Advanced biosensing and bioanalysis techniques
article

Portable Detection of Copper Ion Using Personal Glucose Meter

Haijun Chen, Anqi Huang, Bin Du, Wei Liu, Taoying Chen
article en

Abstract

A simple and sensitive method for Cu<sup>2+</sup> detection was developed using the Cu<sup>+</sup>-catalyzed alkyne-azide cycloaddition reaction, Fe<sub>3</sub>O<sub>4</sub> magnetic nanoparticles (MNPs) as the reaction platform, and a portable blood glucose meter (PGM) as the detection method. Gold nanoparticles (AuNPs) were labeled with glucose oxidase (GOx) and alkyne-functionalized, terminally thiolated ssDNA (C2). In the presence of Cu<sup>2+</sup> and ascorbate, the functionalized AuNPs were captured onto MNPs modified with azide-functionalized ssDNA (C1) via the Cu<sup>+</sup>-catalyzed alkyne-azide cycloaddition reaction. The GOx on the AuNPs' surface oxidized glucose (Glu) into gluconic acid and H<sub>2</sub>O<sub>2</sub>, reducing the Glu content in the reaction solution, which was quantitatively detected by the PGM. Under optimal conditions, the PGM response of the system showed a good linear relationship with the logarithm of Cu<sup>2+</sup> concentration in the range of 0.05 to 10.00 μmol/L, with a detection limit of 0.03 μmol/L (3σ). In actual tap water samples, the spiked recovery rate of Cu<sup>2+</sup> was between 92.30% and 113.33%, and the relative standard deviation was between 0.14% and 0.34%, meeting the detection requirements for Cu<sup>2+</sup> in real water samples.

SensorsVol. 24(21)
Medical College of Wisconsin (US), Guiyang University (CN)
Guizhou Science and Technology Department, Guiyang University
Openalex Percentile: Top 83%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.