Evaluating MIR and NIR Spectroscopy Coupled with Multivariate Analysis for Detection and Quantification of Additives in Tobacco Products

The detection and quantification of additives in tobacco products are critical for ensuring consumer safety and compliance with regulatory standards. Traditional analytical techniques, like gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), and others, although effective, suffer from drawbacks, including complex sample preparation, high costs, lengthy analysis times, and the requirement for skilled operators. This study addresses these challenges by evaluating the efficacy of mid-infrared (MIR) spectroscopy and near-IR (NIR) spectroscopy, coupled with multivariate analysis, as potential solutions for the detection and quantification of additives in tobacco products. So, a representative set of tobacco products was selected and spiked with the targeted additives, namely caffeine, menthol, glycerol, and cocoa. Multivariate analysis of MIR and NIR spectra consisted of principal component analysis (PCA), hierarchical clustering analysis (HCA), partial least squares-discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) to classify samples based on targeted additives. Based on the unsupervised techniques (PCA and HCA), a distinction could be made between spiked and non-spiked samples for all four targeted additives based on both MIR and NIR spectral data. During supervised analysis, SIMCA achieved 87-100% classification accuracy for the different additives and for both spectroscopic techniques. PLS-DA models showed classification rates of 80% to 100%, also demonstrating robust performance. Regression studies, using PLS, showed that it is possible to effectively estimate the concentration levels of the targeted molecules. The results also highlight the necessity of optimizing data pretreatment for accurate quantification of the target additives. Overall, NIR spectroscopy combined with SIMCA provided the most accurate and robust classification models for all target molecules, indicating that it is the most effective single technique for this type of analysis. MIR, on the other hand, showed the overall best performance for quantitative estimation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-10-31
DOI
https://doi.org/10.3390/s24217018
Citations
3
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating MIR and NIR Spectroscopy Coupled with Multivariate Analysis for Detection and Quantification of Additives in Tobacco Products

Céline Vanhee, Michaël Canfyn, Erwin Adams, Cédric Delporte et al.
3 citations
Sensors
Spectroscopy and Chemometric Analyses
0.71
article

Evaluating MIR and NIR Spectroscopy Coupled with Multivariate Analysis for Detection and Quantification of Additives in Tobacco Products

Céline Vanhee, Michaël Canfyn, Erwin Adams, Cédric Delporte, Zeb Akhtar, Eric Deconinck
article en
3 citations

Abstract

The detection and quantification of additives in tobacco products are critical for ensuring consumer safety and compliance with regulatory standards. Traditional analytical techniques, like gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), and others, although effective, suffer from drawbacks, including complex sample preparation, high costs, lengthy analysis times, and the requirement for skilled operators. This study addresses these challenges by evaluating the efficacy of mid-infrared (MIR) spectroscopy and near-IR (NIR) spectroscopy, coupled with multivariate analysis, as potential solutions for the detection and quantification of additives in tobacco products. So, a representative set of tobacco products was selected and spiked with the targeted additives, namely caffeine, menthol, glycerol, and cocoa. Multivariate analysis of MIR and NIR spectra consisted of principal component analysis (PCA), hierarchical clustering analysis (HCA), partial least squares-discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) to classify samples based on targeted additives. Based on the unsupervised techniques (PCA and HCA), a distinction could be made between spiked and non-spiked samples for all four targeted additives based on both MIR and NIR spectral data. During supervised analysis, SIMCA achieved 87-100% classification accuracy for the different additives and for both spectroscopic techniques. PLS-DA models showed classification rates of 80% to 100%, also demonstrating robust performance. Regression studies, using PLS, showed that it is possible to effectively estimate the concentration levels of the targeted molecules. The results also highlight the necessity of optimizing data pretreatment for accurate quantification of the target additives. Overall, NIR spectroscopy combined with SIMCA provided the most accurate and robust classification models for all target molecules, indicating that it is the most effective single technique for this type of analysis. MIR, on the other hand, showed the overall best performance for quantitative estimation.

SensorsVol. 24(21)
Université Libre de Bruxelles (BE), Directorate-General for Health and Food Safety (BE), Sciensano (Belgium) (BE), KU Leuven (BE)
Good health and well-being
Openalex Percentile: Top 34%
Spectroscopy and Chemometric Analyses
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.