Advanced Noise-Resistant Electrocardiography Classification Using Hybrid Wavelet-Median Denoising and a Convolutional Neural Network

The classification of ECG signals is a critical process because it guides the diagnosis of the proper treatment process for the patient. However, any form of disturbance with ECG signals can be highly conspicuous because of the mechanics involved in data acquisition from living beings, which has a significant impact on the classification procedure. The purpose of this research work is to advance ECG signal classification results by employing numerous denoising methods and, in turn, boost the accuracy of cardiovascular diagnoses. To simulate realistic conditions, we added various types of noise to ECG data, including Gaussian, salt and pepper, speckle, uniform, and exponential noise. To overcome the interference of noise from environments in the obtained ECG signals, we employed wavelet transform, median filter, Gaussian filter, and the hybrid of the wavelet and median filters. The proposed hybrid denoising method has better results than the other methods because of the use of wavelet multi-scale analysis and the ability of the median filter to avoid the loss of vital ECG characteristics. Thus, despite a certain proximity in the values, the hybrid method is significantly more accurate and reliable, as evidenced by the mean squared error (MSE), mean absolute error (MAE), R-squared, and Pearson correlation coefficient. More specifically, the hybrid approach provided an MSE of 0.0012 and an MAE of 0.025, the R-squared value for this study was 0.98, and the Pearson correlation coefficient was 0.99, which provides a very good resemblance to the original ECG confirmation. The proposed classification model is based on the modified lightweight CNN or MLCNN that was trained using the noisy and the denoised data. The findings demonstrated that by applying the denoised data, the testing accuracy, precision, recall, and F1 scores achieved 0.92, 0.91, 0.90, and 0.91 for the datasets, while the noisy data achieved 0.80, 0.78, 0.82, and 0.80, respectively. In this study, the signal quality and denoising methods were found to enhance ECG signal classification and diagnostic accuracy while encouraging proper preprocessing in future studies and applications for real-time ECG for cardiac care.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-10-31
DOI
https://doi.org/10.3390/s24217033
Citations
10
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
4.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Noise-Resistant Electrocardiography Classification Using Hybrid Wavelet-Median Denoising and a Convolutional Neural Network

Neha Agarwal, Hari Mohan, Saurabh Agarwal, Aditya Pal
10 citations
Sensors
ECG Monitoring and Analysis
4.02
article

Advanced Noise-Resistant Electrocardiography Classification Using Hybrid Wavelet-Median Denoising and a Convolutional Neural Network

Neha Agarwal, Hari Mohan, Saurabh Agarwal, Aditya Pal
article en
10 citations

Abstract

The classification of ECG signals is a critical process because it guides the diagnosis of the proper treatment process for the patient. However, any form of disturbance with ECG signals can be highly conspicuous because of the mechanics involved in data acquisition from living beings, which has a significant impact on the classification procedure. The purpose of this research work is to advance ECG signal classification results by employing numerous denoising methods and, in turn, boost the accuracy of cardiovascular diagnoses. To simulate realistic conditions, we added various types of noise to ECG data, including Gaussian, salt and pepper, speckle, uniform, and exponential noise. To overcome the interference of noise from environments in the obtained ECG signals, we employed wavelet transform, median filter, Gaussian filter, and the hybrid of the wavelet and median filters. The proposed hybrid denoising method has better results than the other methods because of the use of wavelet multi-scale analysis and the ability of the median filter to avoid the loss of vital ECG characteristics. Thus, despite a certain proximity in the values, the hybrid method is significantly more accurate and reliable, as evidenced by the mean squared error (MSE), mean absolute error (MAE), R-squared, and Pearson correlation coefficient. More specifically, the hybrid approach provided an MSE of 0.0012 and an MAE of 0.025, the R-squared value for this study was 0.98, and the Pearson correlation coefficient was 0.99, which provides a very good resemblance to the original ECG confirmation. The proposed classification model is based on the modified lightweight CNN or MLCNN that was trained using the noisy and the denoised data. The findings demonstrated that by applying the denoised data, the testing accuracy, precision, recall, and F1 scores achieved 0.92, 0.91, 0.90, and 0.91 for the datasets, while the noisy data achieved 0.80, 0.78, 0.82, and 0.80, respectively. In this study, the signal quality and denoising methods were found to enhance ECG signal classification and diagnostic accuracy while encouraging proper preprocessing in future studies and applications for real-time ECG for cardiac care.

SensorsVol. 24(21)
Gachon University (KR), JRE Group of Institutions (IN), Yeungnam University (KR)
Openalex Percentile: Top 5%
ECG Monitoring and Analysis
4.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.