A Kind of Shielding Design and Verification Test of Radioactive Source Transport Container

Abstract A transport container for radioactive sources has been meticulously designed to facilitate the global transfer of radioactive materials from storage facilities to end-users. In compliance with the stipulations outlined in GB 11806 and the IAEA SSR-6, the radiation dose of the container was meticulously calculated under both normal transport conditions and accident scenarios. Shielding tests were conducted both at the manufacturing site and post-manufacturing. The results of these tests indicated that the surface dose rate was 289 μSv/h prior to testing, which increased to 299.34 μSv/h after testing. Additionally, the radiation level at a distance of 1 meter from the package was measured at 31.59 μ Sv/h. Both the computational and experimental outcomes confirm that the shielding design of the transport container adheres to the relevant standards set forth by GB 11806 and SSR-6.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1115/icone31-136170
Primary Topic
Nuclear and radioactivity studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Kind of Shielding Design and Verification Test of Radioactive Source Transport Container

LiMing Jiao, Qian Sun, Dajie Zhuang, ChangWu Wang et al.
Nuclear and radioactivity studies
article

A Kind of Shielding Design and Verification Test of Radioactive Source Transport Container

LiMing Jiao, Qian Sun, Dajie Zhuang, ChangWu Wang, Lei Chen, Zhipeng Wang
article en

Abstract

Abstract A transport container for radioactive sources has been meticulously designed to facilitate the global transfer of radioactive materials from storage facilities to end-users. In compliance with the stipulations outlined in GB 11806 and the IAEA SSR-6, the radiation dose of the container was meticulously calculated under both normal transport conditions and accident scenarios. Shielding tests were conducted both at the manufacturing site and post-manufacturing. The results of these tests indicated that the surface dose rate was 289 μSv/h prior to testing, which increased to 299.34 μSv/h after testing. Additionally, the radiation level at a distance of 1 meter from the package was measured at 31.59 μ Sv/h. Both the computational and experimental outcomes confirm that the shielding design of the transport container adheres to the relevant standards set forth by GB 11806 and SSR-6.

National Institute for Radiological Protection (CN)
Openalex Percentile: Top 77%
Nuclear and radioactivity studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Kind of Shielding Design and Verification Test of Radioactive Source Transport Container — LiMing Jiao, Qian Sun, et al. · (2024) | TGRS Research Map | TGRS