Droplet Evaporation Characteristics on High-Temperature Porous Surfaces for Cooling Fuel Debris

Abstract Fuel debris at the Fukushima nuclear power station is typically cooled under immersion. However, significant drop in water level results in coolant contact with high-temperature, porous fuel debris. In such scenarios, rapid cooling is essential, yet the thermal behavior at the liquid-solid interface, including capillary phenomena, is not well understood. This paper presents basic research evaluating the evaporation characteristics of droplets upon contact with metallic porous media featuring small pores under 1 mm. We conducted experiments using bronze or stainless steel porous media with pore diameters of 1, 40, or 100 μm to derive lifetime curves for droplets. Our findings indicate that Leidenfrost effect is mitigated on porous surfaces as the vapor can escape through the pores. Moreover, in bronze porous media, as the temperature increases, oxide film with a fine structure facilitates capillary action. In contrast, the low wettability of stainless steel porous media prevents capillary action, inhibiting droplet absorption and dispersion into the pores. Consequently, rapid cooling via the capillary action is unlikely if the fuel debris shares similar characteristics with steel porous media.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1115/icone31-135281
Primary Topic
Fluid Dynamics and Heat Transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Droplet Evaporation Characteristics on High-Temperature Porous Surfaces for Cooling Fuel Debris

Kohei Yuki, Naoki Horiguchi, Hiroyuki Yoshida, Kazuhisa Yuki
Fluid Dynamics and Heat Transfer
article

Droplet Evaporation Characteristics on High-Temperature Porous Surfaces for Cooling Fuel Debris

Kohei Yuki, Naoki Horiguchi, Hiroyuki Yoshida, Kazuhisa Yuki
article en

Abstract

Abstract Fuel debris at the Fukushima nuclear power station is typically cooled under immersion. However, significant drop in water level results in coolant contact with high-temperature, porous fuel debris. In such scenarios, rapid cooling is essential, yet the thermal behavior at the liquid-solid interface, including capillary phenomena, is not well understood. This paper presents basic research evaluating the evaporation characteristics of droplets upon contact with metallic porous media featuring small pores under 1 mm. We conducted experiments using bronze or stainless steel porous media with pore diameters of 1, 40, or 100 μm to derive lifetime curves for droplets. Our findings indicate that Leidenfrost effect is mitigated on porous surfaces as the vapor can escape through the pores. Moreover, in bronze porous media, as the temperature increases, oxide film with a fine structure facilitates capillary action. In contrast, the low wettability of stainless steel porous media prevents capillary action, inhibiting droplet absorption and dispersion into the pores. Consequently, rapid cooling via the capillary action is unlikely if the fuel debris shares similar characteristics with steel porous media.

Japan Atomic Energy Agency (JP), Sanyo-Onoda City University (JP)
Openalex Percentile: Top 79%
Fluid Dynamics and Heat Transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.