CFD Simulation of Water Hammer Induced by Condensation Using an Improved Phase Change Model

Abstract A computational fluid dynamics (CFD) based approach using FLUENT is applied to investigate the phenomenon of condensation-induced water hammer (CIWH) caused by direct contact condensation. In these simulations, the two-phase interface is explicitly tracked using the volume of fluid (VOF) method, and a hybrid heat transfer coefficient (HTC) model based on surface renewal theory is employed for interface heat transfer. The HTC model is implemented through user-defined functions (UDFs). The simulation results are compared with experimental data obtained from the PMK-2 facility of the VVER-440/312-type nuclear power plant in Budapest, Hungary. The results demonstrate that the model aligns well with the measured temperature field, as well as the timing and magnitude of pressure peaks. This CFD approach can be utilized for prediction and prevention of CIWH.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1115/icone31-134963
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CFD Simulation of Water Hammer Induced by Condensation Using an Improved Phase Change Model

Shengfei Wang, Jiaming Zhao, Xinping Long, Wentao Guo et al.
1 citations
High voltage insulation and dielectric phenomena
0.12
article

CFD Simulation of Water Hammer Induced by Condensation Using an Improved Phase Change Model

Shengfei Wang, Jiaming Zhao, Xinping Long, Wentao Guo, Zihao Zhang, Peng Li, Feng Xiong, Daping Lin, Zhengyu Chen, Ruiyang Tu
article en
1 citations

Abstract

Abstract A computational fluid dynamics (CFD) based approach using FLUENT is applied to investigate the phenomenon of condensation-induced water hammer (CIWH) caused by direct contact condensation. In these simulations, the two-phase interface is explicitly tracked using the volume of fluid (VOF) method, and a hybrid heat transfer coefficient (HTC) model based on surface renewal theory is employed for interface heat transfer. The HTC model is implemented through user-defined functions (UDFs). The simulation results are compared with experimental data obtained from the PMK-2 facility of the VVER-440/312-type nuclear power plant in Budapest, Hungary. The results demonstrate that the model aligns well with the measured temperature field, as well as the timing and magnitude of pressure peaks. This CFD approach can be utilized for prediction and prevention of CIWH.

North China Electric Power University (CN)
Clean water and sanitation
Openalex Percentile: Top 58%
High voltage insulation and dielectric phenomena
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.