The Self‐Calibrating Tilt Accelerometer: A Method for Observing Tilt and Correcting Drift With a Triaxial Accelerometer

Abstract We present observations from two field deployments of a calibrated tiltmeter that we name the Self‐Calibrating Tilt Accelerometer (SCTA). The tiltmeter is based upon a triaxial quartz crystal accelerometer; the horizontal channels measure tilt and are periodically rotated into the vertical to obtain a measurement of the acceleration of gravity. Changes in the measured total acceleration are ascribed to drift in the vertical channel and used as calibrations for removing that same drift from the tilt time series observed between calibrations. Changes in the span (sensitivity) of the accelerometer channels can also be measured by calibrating them pointing up and down. A 3‐year test on the seafloor at Axial Seamount show that the calibrations are consistent with a linear‐exponential model of drift to a RMS residual of ∼0.5 μg (μrad). The calibrated tilt time series was impacted by platform settling for the first 2 years, but after repositioning the tiltmeter, the calibrated observations were consistent for the final year with the tilt observed on a nearby LILY tiltmeter, within an assumed level of drift for the unconstrained LILY sensor. A separate 15‐month test in a stable vault at Piñon Flat Observatory was complicated by seasonal temperature variations of >5°C; the calibrations are consistent with a linear‐exponential model of drift to ∼2 μg RMS when temperature and temperature time‐derivative dependence is included. Similarly, the calibrated tilt time series was impacted by thermal deformation of the SCTA assembly. A future test in a thermally and tectonically stable borehole will be required to assess the accuracy of the SCTA.

Authors

Institutions

Publication Details

Journal
Earth and Space Science
Published
2024-10-31
DOI
https://doi.org/10.1029/2024ea003909
Citations
2
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
1.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Self‐Calibrating Tilt Accelerometer: A Method for Observing Tilt and Correcting Drift With a Triaxial Accelerometer

J. Tilley, William S. D. Wilcock, Justin Burnett, G. Cram et al.
2 citations
Earth and Space Science
Seismic Waves and Analysis
1.07
article

The Self‐Calibrating Tilt Accelerometer: A Method for Observing Tilt and Correcting Drift With a Triaxial Accelerometer

J. Tilley, William S. D. Wilcock, Justin Burnett, G. Cram, Erik K. Fredrickson, Daniel P. Martin, Michael Harrington
article en
2 citations

Abstract

Abstract We present observations from two field deployments of a calibrated tiltmeter that we name the Self‐Calibrating Tilt Accelerometer (SCTA). The tiltmeter is based upon a triaxial quartz crystal accelerometer; the horizontal channels measure tilt and are periodically rotated into the vertical to obtain a measurement of the acceleration of gravity. Changes in the measured total acceleration are ascribed to drift in the vertical channel and used as calibrations for removing that same drift from the tilt time series observed between calibrations. Changes in the span (sensitivity) of the accelerometer channels can also be measured by calibrating them pointing up and down. A 3‐year test on the seafloor at Axial Seamount show that the calibrations are consistent with a linear‐exponential model of drift to a RMS residual of ∼0.5 μg (μrad). The calibrated tilt time series was impacted by platform settling for the first 2 years, but after repositioning the tiltmeter, the calibrated observations were consistent for the final year with the tilt observed on a nearby LILY tiltmeter, within an assumed level of drift for the unconstrained LILY sensor. A separate 15‐month test in a stable vault at Piñon Flat Observatory was complicated by seasonal temperature variations of >5°C; the calibrations are consistent with a linear‐exponential model of drift to ∼2 μg RMS when temperature and temperature time‐derivative dependence is included. Similarly, the calibrated tilt time series was impacted by thermal deformation of the SCTA assembly. A future test in a thermally and tectonically stable borehole will be required to assess the accuracy of the SCTA.

Earth and Space ScienceVol. 11(11)
University of Washington (US), University of Washington Applied Physics Laboratory (US), The University of Texas at Austin (US)
National Science Foundation
Life below water
Openalex Percentile: Top 24%
Seismic Waves and Analysis
1.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.