Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung

Distributed Generation (DG) is a power plant that is spread over the power distribution network. In principle, electrical power output is generated by power plants located far from the load center and electrical power is transmitted to the load center through transmission and distribution networks. The longer the cable from the power plant or substation, the lower the voltage at the end load. Sub-optimal DG placement and size can result in increased power losses and affect the system voltage profile. In addition, suboptimal generation capacity can lead to voltage instability, reduced system security, and potential impacts on system frequency and emissions. Therefore, this study will use the Artificial Bee Colony (ABC) method to determine the optimal DG capacity and location. In the base case condition, the power losses in the system are 118 KW and 99 Kvar. Power losses after the installation of 1 DG active power loss becomes 37.4 KW and reactive power loss becomes 31.65 Kvar. Placement of 2 DGs reduces active power loss to 17 KW and reactive power loss to 15 Kvar. While the placement of 3 DG reduces active power loss to 33 KW and reactive power loss to 28 KVar.

Authors

Institutions

Publication Details

Journal
Jurnal JEETech
Published
2024-10-28
DOI
https://doi.org/10.32492/jeetech.v5i2.5202
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung

Irrine Budi Sulistiawati, Abraham Lomi, Rahmat Hidayat
Jurnal JEETech
Engineering and Technology Innovations
article

Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung

Irrine Budi Sulistiawati, Abraham Lomi, Rahmat Hidayat
article en

Abstract

Distributed Generation (DG) is a power plant that is spread over the power distribution network. In principle, electrical power output is generated by power plants located far from the load center and electrical power is transmitted to the load center through transmission and distribution networks. The longer the cable from the power plant or substation, the lower the voltage at the end load. Sub-optimal DG placement and size can result in increased power losses and affect the system voltage profile. In addition, suboptimal generation capacity can lead to voltage instability, reduced system security, and potential impacts on system frequency and emissions. Therefore, this study will use the Artificial Bee Colony (ABC) method to determine the optimal DG capacity and location. In the base case condition, the power losses in the system are 118 KW and 99 Kvar. Power losses after the installation of 1 DG active power loss becomes 37.4 KW and reactive power loss becomes 31.65 Kvar. Placement of 2 DGs reduces active power loss to 17 KW and reactive power loss to 15 Kvar. While the placement of 3 DG reduces active power loss to 33 KW and reactive power loss to 28 KVar.

Jurnal JEETechVol. 5(2)
Institut Teknologi Nasional Malang (ID)
Affordable and clean energy
Openalex Percentile: Top 83%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Implementasi Metode Artificial Bee Colony Untuk Penempatan Distributed Generator Pada Penyulang Rayon Tanjung — Irrine Budi Sulistiawati, Abraham Lomi, et al. · Jurnal JEETech (2024) | TGRS Research Map | TGRS