Oscillometric blood pressure measurements on smartphones using vibrometric force estimation

This paper proposes a smartphone-based method for measuring Blood Pressure (BP) using the oscillometric method. For oscillometry, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied of the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on to it. This phenomenon can be recreated using the phone's own vibration motor and measured using the phone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N = 24 proof of concept study of the BP measurement, the smartphone technique achieves a mean absolute error of 9.21 mmHg and 7.77 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-31
DOI
https://doi.org/10.1038/s41598-024-75025-9
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oscillometric blood pressure measurements on smartphones using vibrometric force estimation

Yinan Xuan, Colin Barry, Edward Jay Wang, Alison Moore et al.
2 citations
Scientific Reports
Non-Invasive Vital Sign Monitoring
0.37
article

Oscillometric blood pressure measurements on smartphones using vibrometric force estimation

Yinan Xuan, Colin Barry, Edward Jay Wang, Alison Moore, Ava J. Fascetti
article en
2 citations

Abstract

This paper proposes a smartphone-based method for measuring Blood Pressure (BP) using the oscillometric method. For oscillometry, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied of the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on to it. This phenomenon can be recreated using the phone's own vibration motor and measured using the phone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N = 24 proof of concept study of the BP measurement, the smartphone technique achieves a mean absolute error of 9.21 mmHg and 7.77 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.

Scientific ReportsVol. 14(1)
UC San Diego Health System (US), University of California San Diego (US)
Good health and well-being
Openalex Percentile: Top 42%
Non-Invasive Vital Sign Monitoring
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.