Results of endoscopic electrode removal surgery in patients with cardiovascular implantable electronic devices

Introduction: The increasing popularity of permanent pacemakers and implantable cardioverter defibrillators (ICDs) has improved the quality of life and long-term prognosis of cardiovascular patients. However, there is also an increase in infections of cardiac implantable devices (CIEDs). The infection rate after the first implant is 4.82/1000 people, and after the device replacement is 12.12/1000. With the development of endoscopic techniques, a method of thoroughly treating infections of cardiac implantable devices is opened without increasing the severity of the patient’s condition. Method: Cross-sectional study, 08 patients with pacemaker infection underwent endoscopic surgery at the Cardiovascular Center, E Hospital from January 2020 to July 2024. Result: In 08 patients, the male ratio is mainly 06 patients, the oldest age was 85 years old and the youngest is 25 years old. There are 07 cases with permanent pacemaker implantation, 1 case of ICD placement Brugada syndrome. All cases have bacterial cultures: 05 patients have Staphylococcus aureus and 03 cases have cultured Staphylococcus epidermidis. All patients have pacemaker examination and underwent endoscopic surgery to remove the electrode. The average surgical time is 68,71± 18.3 minutes (97-40), in which 01 case has only electrode probe infection, the remaining cases has both the pacemaker and electrode probe infection. Most stable cases are discharged from hospital with an average time of 16,2± 7,8 days (11-30), 01 severe case due to sepsis in a patient with heart failure EF: 30%, kidney failure, diabetes, hypertension has to stay in treatment for additional 30 days. Conclusion: Endoscopic electrode removal surgery in patients with pacemaker infection initially achieved good results, with low complications and mortality, but a larger number of patients and long-term follow-up and evaluation are needed.

Authors

Publication Details

Journal
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Published
2024-10-25
DOI
https://doi.org/10.47972/vjcts.v48i.1186
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Results of endoscopic electrode removal surgery in patients with cardiovascular implantable electronic devices

Hoang Nam Nguyen, Hai Son Dam, Tran Thuy Nguyen, Nguyễn Hữu Công et al.
Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt Nam
Cardiac pacing and defibrillation studies
article

Results of endoscopic electrode removal surgery in patients with cardiovascular implantable electronic devices

Hoang Nam Nguyen, Hai Son Dam, Tran Thuy Nguyen, Nguyễn Hữu Công, Thanh Dat Pham, Van‐Sang Doan
article en

Abstract

Introduction: The increasing popularity of permanent pacemakers and implantable cardioverter defibrillators (ICDs) has improved the quality of life and long-term prognosis of cardiovascular patients. However, there is also an increase in infections of cardiac implantable devices (CIEDs). The infection rate after the first implant is 4.82/1000 people, and after the device replacement is 12.12/1000. With the development of endoscopic techniques, a method of thoroughly treating infections of cardiac implantable devices is opened without increasing the severity of the patient’s condition. Method: Cross-sectional study, 08 patients with pacemaker infection underwent endoscopic surgery at the Cardiovascular Center, E Hospital from January 2020 to July 2024. Result: In 08 patients, the male ratio is mainly 06 patients, the oldest age was 85 years old and the youngest is 25 years old. There are 07 cases with permanent pacemaker implantation, 1 case of ICD placement Brugada syndrome. All cases have bacterial cultures: 05 patients have Staphylococcus aureus and 03 cases have cultured Staphylococcus epidermidis. All patients have pacemaker examination and underwent endoscopic surgery to remove the electrode. The average surgical time is 68,71± 18.3 minutes (97-40), in which 01 case has only electrode probe infection, the remaining cases has both the pacemaker and electrode probe infection. Most stable cases are discharged from hospital with an average time of 16,2± 7,8 days (11-30), 01 severe case due to sepsis in a patient with heart failure EF: 30%, kidney failure, diabetes, hypertension has to stay in treatment for additional 30 days. Conclusion: Endoscopic electrode removal surgery in patients with pacemaker infection initially achieved good results, with low complications and mortality, but a larger number of patients and long-term follow-up and evaluation are needed.

Tạp chí Phẫu thuật và Tim mạch và Lồng ngực Việt NamVol. 48
Good health and well-being
Openalex Percentile: Top 64%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.