Determination of indacaterol from inhaler capsules by square-wave voltammetry at the surface of the boron-doped diamond electrode

This research paper presents an electroanalytical investigation using the voltammetric method to quantify indacaterol maleate (IND) employing an unmodified boron-doped diamond (BDD) electrode. IND exhibited a distinct, irreversible oxidation peak at approximately 1.06 V (vs. Ag/AgCl) in a 0.1 mol L-1 phosphate buffer solution (PBS) with a pH of 2.5, as demonstrated by cyclic voltammetry (CV). A hypothetical mechanism for the electro-oxidation of IND, based on data gathered from CV investigations, was suggested. The square wave-adsorptive stripping voltammetric technique achieved acceptable linearity in PBS (pH 2.5) at approximately 0.90 V. The methodology demonstrated linearity within the concentration range of 1.0 to 30.0 ?g mL-1 (equivalent to 1.97?10-6?5.89?10-5 mol L-1) and yielded a limit of detection (LOD) of 0.22 ?g mL-1 (equivalent to 4.33?10-7 mol L-1). The proposed method?s applicability was assessed through the sensing of IND in drug formulations.

Authors

Institutions

Publication Details

Journal
Journal of the Serbian Chemical Society
Published
2024-10-31
DOI
https://doi.org/10.2298/jsc240221090b
Citations
13
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
3.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of indacaterol from inhaler capsules by square-wave voltammetry at the surface of the boron-doped diamond electrode

Hoshyar Saadi Ali, Hemn A.H. Barzani, Yavuz Yardım
13 citations
Journal of the Serbian Chemical Society
Analytical Chemistry and Sensors
3.76
article

Determination of indacaterol from inhaler capsules by square-wave voltammetry at the surface of the boron-doped diamond electrode

Hoshyar Saadi Ali, Hemn A.H. Barzani, Yavuz Yardım
article en
13 citations

Abstract

This research paper presents an electroanalytical investigation using the voltammetric method to quantify indacaterol maleate (IND) employing an unmodified boron-doped diamond (BDD) electrode. IND exhibited a distinct, irreversible oxidation peak at approximately 1.06 V (vs. Ag/AgCl) in a 0.1 mol L-1 phosphate buffer solution (PBS) with a pH of 2.5, as demonstrated by cyclic voltammetry (CV). A hypothetical mechanism for the electro-oxidation of IND, based on data gathered from CV investigations, was suggested. The square wave-adsorptive stripping voltammetric technique achieved acceptable linearity in PBS (pH 2.5) at approximately 0.90 V. The methodology demonstrated linearity within the concentration range of 1.0 to 30.0 ?g mL-1 (equivalent to 1.97?10-6?5.89?10-5 mol L-1) and yielded a limit of detection (LOD) of 0.22 ?g mL-1 (equivalent to 4.33?10-7 mol L-1). The proposed method?s applicability was assessed through the sensing of IND in drug formulations.

Journal of the Serbian Chemical SocietyVol. 90(1)
Van Yüzüncü Yıl Üniversitesi (TR), Lebanese French University (IQ)
Openalex Percentile: Top 6%
Analytical Chemistry and Sensors
3.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of indacaterol from inhaler capsules by square-wave voltammetry at the surface of the boron-doped diamond electrode — Hoshyar Saadi Ali, Hemn A.H. Barzani, et al. · Journal of the Serbian Chemical Society (2024) | TGRS Research Map | TGRS