Porous PDMS–ZnO Wearable Gas Sensor for Acetone Biomarker Detection and Breath Analysis

In response to the growing demand for global health monitoring, we report a nonintrusive health detection method using a compact, conformal wearable ultraviolet (UV)-assisted gas-sensing system based on an intrinsically flexible porous polydimethylsiloxane (PDMS)-zinc oxide (ZnO) composite layer (PPZL) for the breath acetone (BrAce) detection and breath event analysis. The enhanced acetone response is attributed to the synergistic effect of UV irradiation and the high surface area of the porous structure, which also improves the mechanical robustness. The UV-assisted wearable sensor reliably detects acetone concentrations ranging from 1 to 100 ppm at room temperature under 4.05 mW/cm<sup>2</sup> UV intensity, even under mechanical strains such as a bending radius of 5 mm and 60% tensile strain. It accurately analyzes different breathing patterns (12-20 breaths per minute) and BrAce concentrations, maintaining a stable performance over 20 days with less than 5% signal degradation. The sensor exhibits response and recovery times of average 110-150 and 130-180 s, respectively, and maintains a consistent 3 ppm BrAce response under varying humidity levels up to 70% relative humidity, ensuring accurate detection of BrAce concentrations during real-world breath tests. Additionally, the sensor targets only specific gases, and the sensor's selectivity is not a key concern. This flexible acetone gas sensor offers a portable solution for health management and a fabrication method for designing flexible metal oxide materials.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2024-10-31
DOI
https://doi.org/10.1021/acsami.4c16209
Citations
23
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
4.24

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Porous PDMS–ZnO Wearable Gas Sensor for Acetone Biomarker Detection and Breath Analysis

Yuhan Liu, Hanxiao Liu, Qisen Xie, Wenjie Zhang et al.
23 citations
ACS Applied Materials & Interfaces
Advanced Chemical Sensor Technologies
4.24
article

Porous PDMS–ZnO Wearable Gas Sensor for Acetone Biomarker Detection and Breath Analysis

Yuhan Liu, Hanxiao Liu, Qisen Xie, Wenjie Zhang, Yixin Liu, Min Zhang, Yanru Chen, Yuzhen Li, Shuhong Cao, Dongkai Wang, Xiaohao Wang, Jiaqi Liu, Liuyang Han
article en
23 citations

Abstract

In response to the growing demand for global health monitoring, we report a nonintrusive health detection method using a compact, conformal wearable ultraviolet (UV)-assisted gas-sensing system based on an intrinsically flexible porous polydimethylsiloxane (PDMS)-zinc oxide (ZnO) composite layer (PPZL) for the breath acetone (BrAce) detection and breath event analysis. The enhanced acetone response is attributed to the synergistic effect of UV irradiation and the high surface area of the porous structure, which also improves the mechanical robustness. The UV-assisted wearable sensor reliably detects acetone concentrations ranging from 1 to 100 ppm at room temperature under 4.05 mW/cm<sup>2</sup> UV intensity, even under mechanical strains such as a bending radius of 5 mm and 60% tensile strain. It accurately analyzes different breathing patterns (12-20 breaths per minute) and BrAce concentrations, maintaining a stable performance over 20 days with less than 5% signal degradation. The sensor exhibits response and recovery times of average 110-150 and 130-180 s, respectively, and maintains a consistent 3 ppm BrAce response under varying humidity levels up to 70% relative humidity, ensuring accurate detection of BrAce concentrations during real-world breath tests. Additionally, the sensor targets only specific gases, and the sensor's selectivity is not a key concern. This flexible acetone gas sensor offers a portable solution for health management and a fabrication method for designing flexible metal oxide materials.

ACS Applied Materials & InterfacesVol. 16(45)
University Town of Shenzhen (CN), Tsinghua University (CN)
Shenzhen Fundamental Research Program
Openalex Percentile: Top 5%
Advanced Chemical Sensor Technologies
4.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.