Characterization of EJ-276D plastic scintillator and its comparison with EJ-299-33A and BC-501A

Abstract A characteristic study of the new generation EJ-276D plastic scintillator detector, measuring 5 inches in diameter and 5 inches in length, was conducted. This study compared it with the earlier EJ-299-33A plastic scintillator and the BC-501A liquid scintillator. Key characteristics such as pulse height response, pulse shape discrimination, efficiency, and time resolution were measured and compared for each detector of the same dimensions. The results show that the performance of EJ-276D is superior to EJ-299-33A in every aspect. It exhibits comparable efficiency but lower pulse shape discrimination capabilities compared to the BC-501A liquid scintillator. Notably, the stability of the EJ-276D over time was also studied and found to be satisfactory.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-10-01
DOI
https://doi.org/10.1088/1748-0221/19/10/p10036
Citations
5
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of EJ-276D plastic scintillator and its comparison with EJ-299-33A and BC-501A

K. Banerjee, P. Pant, Pratap Roy, A. Saha et al.
5 citations
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
3.04
article

Characterization of EJ-276D plastic scintillator and its comparison with EJ-299-33A and BC-501A

K. Banerjee, P. Pant, Pratap Roy, A. Saha, R. Shil
article en
5 citations

Abstract

Abstract A characteristic study of the new generation EJ-276D plastic scintillator detector, measuring 5 inches in diameter and 5 inches in length, was conducted. This study compared it with the earlier EJ-299-33A plastic scintillator and the BC-501A liquid scintillator. Key characteristics such as pulse height response, pulse shape discrimination, efficiency, and time resolution were measured and compared for each detector of the same dimensions. The results show that the performance of EJ-276D is superior to EJ-299-33A in every aspect. It exhibits comparable efficiency but lower pulse shape discrimination capabilities compared to the BC-501A liquid scintillator. Notably, the stability of the EJ-276D over time was also studied and found to be satisfactory.

Journal of InstrumentationVol. 19(10)
Variable Energy Cyclotron Centre (IN), Visva-Bharati University (IN), Homi Bhabha National Institute (IN)
Openalex Percentile: Top 9%
Radiation Detection and Scintillator Technologies
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of EJ-276D plastic scintillator and its comparison with EJ-299-33A and BC-501A — K. Banerjee, P. Pant, et al. · Journal of Instrumentation (2024) | TGRS Research Map | TGRS