Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications

<b>Background:</b> Fluoroscopy-guided PTNB for fluoroscopy-identifiable lung lesions has been suggested as a useful method for the pathological diagnosis of lung lesions; however, it is lacking in accuracy and safety compared to CT-guided PTNB. Thus, we aimed to investigate the diagnostic accuracy and complications of fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) with the aid of pre-procedural planning cone-beam computed tomography (CBCT) in order to take advantage of their respective strengths. <b>Methods:</b> A total of 255 fluoroscopy-guided PTNBs with the aid of planning CBCT were performed. Pre-procedural planning CBCT was conducted to calculate the shortest length from the skin puncture site to the margin of the target lesion for the needle trajectory. No intra-procedural CBCT was performed. The diagnostic performance of fluoroscopy-guided PTNB with the aid of planning CBCT was calculated. The prognostic factors for diagnostic failures and complications were evaluated using logistic regression analysis. <b>Results:</b> The accuracy, sensitivity, specificity, PPV, and NPV were 97.3%, 88.0%, 90.9%, 100%, and 62.5%, respectively. There were 29 diagnostic failures (11.8%), and the multivariable analysis showed that a longer lesion depth on CBCT and a shorter specimen length were each associated with diagnostic failure (<i>p</i> = 0.010 and 0.012, respectively). Complications occurred in 34 PTNBs (13.3%). The multivariable analysis showed that an increased total number of biopsies per lesion, a longer length of lung aeration via needle insertion, a smaller lesion size on CT imaging (≤20 mm), and the presence of an air bronchogram were associated with the occurrence of complications (<i>p</i> = 0.027, <0.001, 0.003, and 0.020, respectively). <b>Conclusions:</b> Excellent diagnostic accuracy was obtained by fluoroscopy-guided PTNB with the aid of planning CBCT. Compared to that of CT- or CBCT-guided PTNB, the procedure-related complication rate was acceptably low, but the radiation dose to patients could be potentially reduced.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-10-31
DOI
https://doi.org/10.3390/diagnostics14212441
Citations
3
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications

Yeo Jin Kim, Je Ryung Gil, Injoong Kim, Young Lee et al.
3 citations
Diagnostics
Lung Cancer Diagnosis and Treatment
1.26
article

Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications

Yeo Jin Kim, Je Ryung Gil, Injoong Kim, Young Lee, Hyun Jung Yoon, Sang Hyun Cho
article en
3 citations

Abstract

<b>Background:</b> Fluoroscopy-guided PTNB for fluoroscopy-identifiable lung lesions has been suggested as a useful method for the pathological diagnosis of lung lesions; however, it is lacking in accuracy and safety compared to CT-guided PTNB. Thus, we aimed to investigate the diagnostic accuracy and complications of fluoroscopy-guided percutaneous transthoracic needle biopsy (PTNB) with the aid of pre-procedural planning cone-beam computed tomography (CBCT) in order to take advantage of their respective strengths. <b>Methods:</b> A total of 255 fluoroscopy-guided PTNBs with the aid of planning CBCT were performed. Pre-procedural planning CBCT was conducted to calculate the shortest length from the skin puncture site to the margin of the target lesion for the needle trajectory. No intra-procedural CBCT was performed. The diagnostic performance of fluoroscopy-guided PTNB with the aid of planning CBCT was calculated. The prognostic factors for diagnostic failures and complications were evaluated using logistic regression analysis. <b>Results:</b> The accuracy, sensitivity, specificity, PPV, and NPV were 97.3%, 88.0%, 90.9%, 100%, and 62.5%, respectively. There were 29 diagnostic failures (11.8%), and the multivariable analysis showed that a longer lesion depth on CBCT and a shorter specimen length were each associated with diagnostic failure (<i>p</i> = 0.010 and 0.012, respectively). Complications occurred in 34 PTNBs (13.3%). The multivariable analysis showed that an increased total number of biopsies per lesion, a longer length of lung aeration via needle insertion, a smaller lesion size on CT imaging (≤20 mm), and the presence of an air bronchogram were associated with the occurrence of complications (<i>p</i> = 0.027, <0.001, 0.003, and 0.020, respectively). <b>Conclusions:</b> Excellent diagnostic accuracy was obtained by fluoroscopy-guided PTNB with the aid of planning CBCT. Compared to that of CT- or CBCT-guided PTNB, the procedure-related complication rate was acceptably low, but the radiation dose to patients could be potentially reduced.

DiagnosticsVol. 14(21)
Veterans Health Service Medical Center (KR)
Good health and well-being
Openalex Percentile: Top 18%
Lung Cancer Diagnosis and Treatment
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.