Analysis of the Heat Transfer Performance of a Buried Pipe in the Heating Season Based on Field Testing

Ground source heat pump (GSHP) systems have been widely used in the field of shallow geothermal heating and cooling because of their high thermal efficiency and environmental friendliness. A borehole heat exchanger (BHE) is the key part of a ground source heat pump system, and its performance and investment cost have a direct and significant impact on the performance and cost of the whole system. The ground temperature gradient, air temperature, seepage flow rate, and injection flow rate affect the heat exchange performance of BHEs, but most of the research on BHEs lacks field test verification. Therefore, this study relied on the results of a field thermal response test (TRT) based on a distributed optical fiber temperature sensor (DOFTS) and site hydrological, geological, and geothermal data to establish a corrected numerical model of buried pipe heat transfer and carry out the heat transfer performance analysis of a buried pipe in the heating season. The results showed that the ground temperature gradient of the test site was about 3.0 °C/100 m, and the temperature of the constant-temperature layer was about 9.17 °C. Increasing the air temperature could improve the heat transfer performance. The temperature of the surrounding rock and soil mass of the single pipe spread uniformly, and the closer it was to the buried pipe, the lower the temperature. When there is groundwater seepage, the seepage carries the cold energy generated by a buried pipe’s heat transfer through heat convection to form a plume zone, which can effectively alleviate the phenomenon of cold accumulation. With an increase in seepage velocity, the heat transfer of the buried pipe increases nonlinearly. The heat transfer performance can be improved by appropriately reducing the temperature and velocity of the injected fluid. Selecting a backfill material with higher thermal conductivity than the ground body can improve the heat transfer performance. These research results can provide support for the optimization of the heat transfer performance of a buried tube heat exchanger.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-10-31
DOI
https://doi.org/10.3390/en17215466
Citations
2
Primary Topic
Laser and Thermal Forming Techniques
Type
article
Field-Weighted Citation Impact
0.75

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Heat Transfer Performance of a Buried Pipe in the Heating Season Based on Field Testing

Hao Deng, Yibin Huang, Fengxia Hu, Echuan Yan et al.
2 citations
Energies
Laser and Thermal Forming Techniques
0.75
article

Analysis of the Heat Transfer Performance of a Buried Pipe in the Heating Season Based on Field Testing

Hao Deng, Yibin Huang, Fengxia Hu, Echuan Yan, Jianguo Kang, Yu Zhang, Jingyong Wang, Jixiang Guo, Xin Zhang, Xuefeng Gao, Jianqiao Zheng, Haoxin Shi, Yongjie Ma
article en
2 citations

Abstract

Ground source heat pump (GSHP) systems have been widely used in the field of shallow geothermal heating and cooling because of their high thermal efficiency and environmental friendliness. A borehole heat exchanger (BHE) is the key part of a ground source heat pump system, and its performance and investment cost have a direct and significant impact on the performance and cost of the whole system. The ground temperature gradient, air temperature, seepage flow rate, and injection flow rate affect the heat exchange performance of BHEs, but most of the research on BHEs lacks field test verification. Therefore, this study relied on the results of a field thermal response test (TRT) based on a distributed optical fiber temperature sensor (DOFTS) and site hydrological, geological, and geothermal data to establish a corrected numerical model of buried pipe heat transfer and carry out the heat transfer performance analysis of a buried pipe in the heating season. The results showed that the ground temperature gradient of the test site was about 3.0 °C/100 m, and the temperature of the constant-temperature layer was about 9.17 °C. Increasing the air temperature could improve the heat transfer performance. The temperature of the surrounding rock and soil mass of the single pipe spread uniformly, and the closer it was to the buried pipe, the lower the temperature. When there is groundwater seepage, the seepage carries the cold energy generated by a buried pipe’s heat transfer through heat convection to form a plume zone, which can effectively alleviate the phenomenon of cold accumulation. With an increase in seepage velocity, the heat transfer of the buried pipe increases nonlinearly. The heat transfer performance can be improved by appropriately reducing the temperature and velocity of the injected fluid. Selecting a backfill material with higher thermal conductivity than the ground body can improve the heat transfer performance. These research results can provide support for the optimization of the heat transfer performance of a buried tube heat exchanger.

EnergiesVol. 17(21)
Jilin University (CN), China University of Mining and Technology (CN), China University of Geosciences (CN), Zhengzhou University (CN), PowerChina (China) (CN), Powerchina Huadong Engineering Corporation (China) (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, National Key Research and Development Program of China
Openalex Percentile: Top 32%
Laser and Thermal Forming Techniques
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.