ENHANCEMENT OF SENSITIVITY, DETECTION RANGE, AND DETECTION LIMIT USING GA METHOD POTENTIOMETRIC BIOSENSOR WITH UREASE ENZYME IMMOBILIZATION TECHNIQUE ON PVA

This study aims to increase the sensitivity range of the width of the UV-Vis absorbance peak with Glutaraldehyde (GA) crosslinking and useful to determine the level of urea in the urine. The potentiometer cell consists of an indicator electrode and a reference electrode. The indicator electrode is denoted PVA-Enzyme/GA/PVC-KTpCIPB, meaning PVA-Enzim as the first layer, GA as the second layer and PVC-KTpCIPB as the third layer. Biosensor with urease enzyme immobilization technique analyzed variations of urea 10-7-10-1 M. The potentiometric method of the biosensor detects signal and voltage (potentiometer cell). The signals that were analyzed for signal variables were symmetrical up and down signals of 2000 signals/second. Voltage was carried out by linear curve analysis, the results of linear curve analysis were the range of detection from a concentration of 10-4-10-2 M with cross-linked GA which increased the absorbance, the detection limit was 10-4 M, the sensitivity was 46.67 mV/ war reversibly and R squared (R2) which is 0.9839 is close to linear.

Authors

Institutions

Publication Details

Journal
EINSTEIN e-JOURNAL
Published
2024-10-31
DOI
https://doi.org/10.24114/eins.v12i3.48873
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ENHANCEMENT OF SENSITIVITY, DETECTION RANGE, AND DETECTION LIMIT USING GA METHOD POTENTIOMETRIC BIOSENSOR WITH UREASE ENZYME IMMOBILIZATION TECHNIQUE ON PVA

Abd Hakim S, Willi Firmando Sibarani
EINSTEIN e-JOURNAL
Analytical Chemistry and Sensors
article

ENHANCEMENT OF SENSITIVITY, DETECTION RANGE, AND DETECTION LIMIT USING GA METHOD POTENTIOMETRIC BIOSENSOR WITH UREASE ENZYME IMMOBILIZATION TECHNIQUE ON PVA

Abd Hakim S, Willi Firmando Sibarani
article en

Abstract

This study aims to increase the sensitivity range of the width of the UV-Vis absorbance peak with Glutaraldehyde (GA) crosslinking and useful to determine the level of urea in the urine. The potentiometer cell consists of an indicator electrode and a reference electrode. The indicator electrode is denoted PVA-Enzyme/GA/PVC-KTpCIPB, meaning PVA-Enzim as the first layer, GA as the second layer and PVC-KTpCIPB as the third layer. Biosensor with urease enzyme immobilization technique analyzed variations of urea 10-7-10-1 M. The potentiometric method of the biosensor detects signal and voltage (potentiometer cell). The signals that were analyzed for signal variables were symmetrical up and down signals of 2000 signals/second. Voltage was carried out by linear curve analysis, the results of linear curve analysis were the range of detection from a concentration of 10-4-10-2 M with cross-linked GA which increased the absorbance, the detection limit was 10-4 M, the sensitivity was 46.67 mV/ war reversibly and R squared (R2) which is 0.9839 is close to linear.

EINSTEIN e-JOURNALVol. 12(3)
State University of Medan (ID)
Openalex Percentile: Top 80%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines