Quality Performance of X-Ray Aircraft Using Fuzzy Logic Based on Linear Regression

History records several adverse effects on the human body due to X-ray exposure. In 1897 in America, 69 cases of skin damage due to X-rays were reported, while in 1902 the number reported increased to 170 cases. In 1911 in Germany, 94 cases of tumors due to X-rays were also reported. This problem is caused by deviations in the accuracy of the X-ray output. To meet the requirements of the right standards, a suitability test is required on the X-ray machine. The purpose of this experiment is to obtain the best radiographic quality by evaluating optimal parameters such as kVp, mA, and exposure time so that the radiation output value is still within the tolerance limit. The methods used are linear regression and fuzzy logic, which are techniques for constructing line graphs between two data variables, namely x and y, where x is the setting and y is the measurement result, then the difference value (error) is obtained. The results of the difference values are grouped based on the passing value of the X-ray suitability test in table 1. From the results obtained, the % error value tested is a value below e-Max 10%, namely the average error % kVp of 1.47%, mA 0.078%, and t 2.35%, meaning that if converted to fuzzy logic, the radiation output quality value is very good.

Authors

Institutions

Publication Details

Published
2024-08-29
DOI
https://doi.org/10.1109/icitisee63424.2024.10730570
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quality Performance of X-Ray Aircraft Using Fuzzy Logic Based on Linear Regression

Ria Putri Rahmadani, Andani Achmad, Sri Mawar Said
Medical Imaging and Analysis
article

Quality Performance of X-Ray Aircraft Using Fuzzy Logic Based on Linear Regression

Ria Putri Rahmadani, Andani Achmad, Sri Mawar Said
article en

Abstract

History records several adverse effects on the human body due to X-ray exposure. In 1897 in America, 69 cases of skin damage due to X-rays were reported, while in 1902 the number reported increased to 170 cases. In 1911 in Germany, 94 cases of tumors due to X-rays were also reported. This problem is caused by deviations in the accuracy of the X-ray output. To meet the requirements of the right standards, a suitability test is required on the X-ray machine. The purpose of this experiment is to obtain the best radiographic quality by evaluating optimal parameters such as kVp, mA, and exposure time so that the radiation output value is still within the tolerance limit. The methods used are linear regression and fuzzy logic, which are techniques for constructing line graphs between two data variables, namely x and y, where x is the setting and y is the measurement result, then the difference value (error) is obtained. The results of the difference values are grouped based on the passing value of the X-ray suitability test in table 1. From the results obtained, the % error value tested is a value below e-Max 10%, namely the average error % kVp of 1.47%, mA 0.078%, and t 2.35%, meaning that if converted to fuzzy logic, the radiation output quality value is very good.

Hasanuddin University (ID)
Affordable and clean energy
Openalex Percentile: Top 82%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.