Generation and Assessment of Digital Elevation Models by Combining Sentinel-1A and Sentinel-1B Data in Mountain Glacier Area

The launch of Sentinel-1 satellite introduces a novel approach for synthetic aperture radar (SAR) interferometry (InSAR). However, its capabilities for topographic mapping are reportedly limited. It is very challenging to create high-quality digital elevation models (DEMs) from InSAR data in mountain area. The main goal of the study was to generate a new high-quality DEM by combining Sentinel-1A and Sentinel-1B data with a short temporal baseline and multiple perpendicular baselines from 43 to 143 m. Five DEMs were produced from five interferometric pairs. The five DEMs were fused to generate a more reliable fused DEM. The performance of the new DEMs was evaluated against ICESat-2/ATL06 product and global DEM products (NASADEM, advanced spaceborne thermal emission and reflection radiometer (ASTER) global digital elevation model (GDEM), and advanced land observing satellite ALOS World 3D-30 m). The results showed that all Sentinel-1 DEMs performed better than ASTER GDEM, four of DEMs had higher accuracies than NASADEM. The fused DEM with the vertical error of 9.08 m for steep terrain (slope>20°) revealed higher accuracy than three global DEMs. The accuracy of DEM was related to terrain slope and land cover type. The accuracies of DEMs decreased as slope increased. The DEMs in glacier area revealed higher errors than those in bare rock. Besides, there was no clear relationship between the perpendicular baseline and vertical accuracy of DEM. The interferometric pair with the shortest baseline (43 m) produced the worst quality DEM, while the interferometric pair with slightly shorter baseline (69 m) produced the highest quality DEM. The study revealed the outstanding accuracy of the new DEM product, which is very valuable data for local glacier research.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Published
2024-10-31
DOI
https://doi.org/10.1109/jstars.2024.3489576
Citations
2
Primary Topic
Cryospheric studies and observations
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generation and Assessment of Digital Elevation Models by Combining Sentinel-1A and Sentinel-1B Data in Mountain Glacier Area

Xiaohua Hao, Zhenliang Yin, Junyan Liu, Lili Yan et al.
2 citations
IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Cryospheric studies and observations
0.75
article

Generation and Assessment of Digital Elevation Models by Combining Sentinel-1A and Sentinel-1B Data in Mountain Glacier Area

Xiaohua Hao, Zhenliang Yin, Junyan Liu, Lili Yan, Jian Wang, Hongxing Li
article en
2 citations

Abstract

The launch of Sentinel-1 satellite introduces a novel approach for synthetic aperture radar (SAR) interferometry (InSAR). However, its capabilities for topographic mapping are reportedly limited. It is very challenging to create high-quality digital elevation models (DEMs) from InSAR data in mountain area. The main goal of the study was to generate a new high-quality DEM by combining Sentinel-1A and Sentinel-1B data with a short temporal baseline and multiple perpendicular baselines from 43 to 143 m. Five DEMs were produced from five interferometric pairs. The five DEMs were fused to generate a more reliable fused DEM. The performance of the new DEMs was evaluated against ICESat-2/ATL06 product and global DEM products (NASADEM, advanced spaceborne thermal emission and reflection radiometer (ASTER) global digital elevation model (GDEM), and advanced land observing satellite ALOS World 3D-30 m). The results showed that all Sentinel-1 DEMs performed better than ASTER GDEM, four of DEMs had higher accuracies than NASADEM. The fused DEM with the vertical error of 9.08 m for steep terrain (slope>20°) revealed higher accuracy than three global DEMs. The accuracy of DEM was related to terrain slope and land cover type. The accuracies of DEMs decreased as slope increased. The DEMs in glacier area revealed higher errors than those in bare rock. Besides, there was no clear relationship between the perpendicular baseline and vertical accuracy of DEM. The interferometric pair with the shortest baseline (43 m) produced the worst quality DEM, while the interferometric pair with slightly shorter baseline (69 m) produced the highest quality DEM. The study revealed the outstanding accuracy of the new DEM product, which is very valuable data for local glacier research.

IEEE Journal of Selected Topics in Applied Earth Observations and Remote SensingVol. 18
Chinese Academy of Sciences (CN), Northwest Institute of Eco-Environment and Resources (CN)
Climate action
Openalex Percentile: Top 30%
Cryospheric studies and observations
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.