TlCl:Be,I: A High Sensitivity Scintillation and Cherenkov Radiator for TOF-PET

The material requirements for gamma-ray detectors for medical imaging applications are multi-fold and sensitivity is often overlooked. High effective atomic number (Z<sub>eff</sub>) Cherenkov radiators have raised the attention in the community due to their potential for harvesting prompt photons. A material with one of the highest Z<sub>eff</sub> and thus short gamma-ray attenuation length is thallium chloride (TlCl). By doping TlCl with beryllium (Be) or iodine (I), it becomes a scintillator and therefore produces scintillation photons upon gamma-ray interaction on top of the prompt Cherenkov luminescence. The scintillation response of TlCl:Be,I is investigated in terms of intensity, energy resolution, kinetics, and timing capability with and without energy discrimination. The ratio of prompt to slow scintillation photons is used to derive the intrinsic number of produced Cherenkov photons and compared with analytic calculations avoiding complex Monte-Carlo simulations. The experimentally determined number of Cherenkov photons upon 511 keV gamma excitation of 17.9 ± 4.6 photons is in line with our simple calculations yielding 14.5 photons. We observe three scintillation decay time components with an effective decay time of 60 ns. The scintillation light yield of 0.9 ph/keV is sufficient to discriminate events with low energy deposition in the crystal which is used to improve the measured coincidence time resolution from 360 ps FWHM without energy selection down to 235 ps after energy discrimination and time walk correction for 2.8 mm thick TlCl:Be,I crystals, and from 580 ps to 402 ps for 15.2 mm thick ones. Already with the first generation of doped TlCl encouraging timing capability close to other materials with lower effective atomic number has been achieved.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2024-10-31
DOI
https://doi.org/10.1109/trpms.2024.3487359
Citations
5
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TlCl:Be,I: A High Sensitivity Scintillation and Cherenkov Radiator for TOF-PET

Emilie Roncali, Giulia Terragni, E. Auffray, Lakshmi Soundara Pandian et al.
5 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Radiation Detection and Scintillator Technologies
3.04
article

TlCl:Be,I: A High Sensitivity Scintillation and Cherenkov Radiator for TOF-PET

Emilie Roncali, Giulia Terragni, E. Auffray, Lakshmi Soundara Pandian, Nathaniel Kaneshige, Gerard Ariño‐Estrada, N. Kratochwil, Edgar van Loef, Roberto Calá, J. Głodo, Jared Schott
article en
5 citations

Abstract

The material requirements for gamma-ray detectors for medical imaging applications are multi-fold and sensitivity is often overlooked. High effective atomic number (Z<sub>eff</sub>) Cherenkov radiators have raised the attention in the community due to their potential for harvesting prompt photons. A material with one of the highest Z<sub>eff</sub> and thus short gamma-ray attenuation length is thallium chloride (TlCl). By doping TlCl with beryllium (Be) or iodine (I), it becomes a scintillator and therefore produces scintillation photons upon gamma-ray interaction on top of the prompt Cherenkov luminescence. The scintillation response of TlCl:Be,I is investigated in terms of intensity, energy resolution, kinetics, and timing capability with and without energy discrimination. The ratio of prompt to slow scintillation photons is used to derive the intrinsic number of produced Cherenkov photons and compared with analytic calculations avoiding complex Monte-Carlo simulations. The experimentally determined number of Cherenkov photons upon 511 keV gamma excitation of 17.9 ± 4.6 photons is in line with our simple calculations yielding 14.5 photons. We observe three scintillation decay time components with an effective decay time of 60 ns. The scintillation light yield of 0.9 ph/keV is sufficient to discriminate events with low energy deposition in the crystal which is used to improve the measured coincidence time resolution from 360 ps FWHM without energy selection down to 235 ps after energy discrimination and time walk correction for 2.8 mm thick TlCl:Be,I crystals, and from 580 ps to 402 ps for 15.2 mm thick ones. Already with the first generation of doped TlCl encouraging timing capability close to other materials with lower effective atomic number has been achieved.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 9(3)
Radiation Monitoring Devices (United States) (US), Centre de Recerca Matemàtica (ES), European Organization for Nuclear Research (CH), University of California, Davis (US)
CERN, Bundesministerium für Bildung, Wissenschaft und Forschung, National Institutes of Health
Openalex Percentile: Top 9%
Radiation Detection and Scintillator Technologies
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.