Proposal for a pacemaker implant technique with minimum radiation exposure

Objective: To describe a standardized technique for implanting a pacemaker to reduce the time of surgery and radiation exposure and to demonstrate the results in a series of patients. Methods: Through descriptive and cross-sectional statistics, 109 patients undergoing dual-chamber (DDD) and single-chamber (VVI) pacemaker implantation were evaluated, using a standardized technical approach used in the cardiac surgery service of Santa Casa de Misericórdia of Ponta Grossa-PR, Brazil, from November 2016 to November 2019. Clinical aspects, implant indication, implant times, and radiation time were studied. The technique was described, and its most relevant aspects were discussed. Results: 68.81% of the pacemakers were DDD and the surgical time ranged from 11’22’’ to 34’43’’, with a median of 18’15’’. In these cases, the fluoroscopy time ranged from 34’’ to 5’10’’, with a mean of 1’42’’ and a 16.9 mGy median amount of radiation. The time to implant the VVI pacemaker ranged from 12’ to 42’, with a median of 17’12’’. The fluoroscopy time ranged from 26’’ to 6’25’’, with a mean of 1’41’’ and the median amount of radiation was 13.6 mGy. Conclusion: The technique proved to be agile, safe, with low fluoroscopy times and small amount of radiation. There were no postoperative complications. However, few studies were found for comparison.

Authors

Institutions

Publication Details

Journal
Journal of Cardiac Arrhythmias
Published
2024-10-31
DOI
https://doi.org/10.24207/jca.v37i1.3489
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal for a pacemaker implant technique with minimum radiation exposure

Ana Carolina Mello Fontoura de Souza, Mário Augusto Cray da Costa, Laura Machado, Robson Cesar Vaz Grczczak
Journal of Cardiac Arrhythmias
Cardiac pacing and defibrillation studies
article

Proposal for a pacemaker implant technique with minimum radiation exposure

Ana Carolina Mello Fontoura de Souza, Mário Augusto Cray da Costa, Laura Machado, Robson Cesar Vaz Grczczak
article en

Abstract

Objective: To describe a standardized technique for implanting a pacemaker to reduce the time of surgery and radiation exposure and to demonstrate the results in a series of patients. Methods: Through descriptive and cross-sectional statistics, 109 patients undergoing dual-chamber (DDD) and single-chamber (VVI) pacemaker implantation were evaluated, using a standardized technical approach used in the cardiac surgery service of Santa Casa de Misericórdia of Ponta Grossa-PR, Brazil, from November 2016 to November 2019. Clinical aspects, implant indication, implant times, and radiation time were studied. The technique was described, and its most relevant aspects were discussed. Results: 68.81% of the pacemakers were DDD and the surgical time ranged from 11’22’’ to 34’43’’, with a median of 18’15’’. In these cases, the fluoroscopy time ranged from 34’’ to 5’10’’, with a mean of 1’42’’ and a 16.9 mGy median amount of radiation. The time to implant the VVI pacemaker ranged from 12’ to 42’, with a median of 17’12’’. The fluoroscopy time ranged from 26’’ to 6’25’’, with a mean of 1’41’’ and the median amount of radiation was 13.6 mGy. Conclusion: The technique proved to be agile, safe, with low fluoroscopy times and small amount of radiation. There were no postoperative complications. However, few studies were found for comparison.

Journal of Cardiac ArrhythmiasVol. 37
Universidade Estadual de Ponta Grossa (BR)
Good health and well-being
Openalex Percentile: Top 65%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Proposal for a pacemaker implant technique with minimum radiation exposure — Ana Carolina Mello Fontoura de Souza, Mário Augusto Cray da Costa, et al. · Journal of Cardiac Arrhythmias (2024) | TGRS Research Map | TGRS