DAMAGE CONTROL AND EVALUATION OF PRECAST CONCRETE BEAMS POST-TENSIONED BY UNBONDED TENDONS AT WIDENED BEAM END
In this study, damage control for precast concrete beams post-tensioned by unbonded tendons at widened beam ends were investigated through loading tests and numerical analysis. The use of steel-fiber reinforced concrete reduced the damage during post-tensioning. The use of indented PC steel strands suppressed damage at drift angles of more than 3%. Based on the experimental results, the limit state was judged, and it was found that most of the limit states were determined by the concrete. The numerical analysis model using the fiber model could trace the hysteretic loop and the drift angle at limit state with good accuracy.
Authors
- Ryo Yamada (ORCID: https://orcid.org/0000-0002-1587-630X)
- Kentaro MATSUNAGA
- Kenji TANO
- Y. Horiguchi (ORCID: https://orcid.org/0000-0002-6748-9643)
- Masanori Tani (ORCID: https://orcid.org/0000-0002-3190-7006)
- Aoi FURUSAWA
Institutions
- Kyoto University (JP)
- Kyoto Architecture University (JP)
- Mitsui (Japan) (JP)
Publication Details
- Journal
- Journal of Structural and Construction Engineering (Transactions of AIJ)
- Published
- 2024-10-31
- DOI
- https://doi.org/10.3130/aijs.89.1308
- Primary Topic
- Structural Behavior of Reinforced Concrete
- Type
- article
- Field-Weighted Citation Impact
- 0.00