Analysis of Conducting Waves Using Multi-channel Surface EMG Depends on Electrodes in Multiple Directions

The purpose of this study is to consider the difference in the characteristics of conducting waves depending on the electrode width and direction. The electrodes proposed array electrodes that have five electrodes with widths of 10, 9, 8, 7, and 6 mm arranged in a fan shape. By incorporating a DIP switch between the electrode and the amplifier and turning it ON (short circuit), it is possible to change the electrode shape without replacing it. The analysis used the multi-channel method. As a result, when all are short-circuited, it is possible to estimate the mixing of noise in each channel. It was found that an averaged conducting wave can be obtained by widening the electrode width. In addition, from the result of more conducting waves can be extracted from the electrodes attached in the direction of the muscle fibers, it is possible to estimate the direction of the muscle fibers.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Electronics Information and Systems
Published
2024-10-31
DOI
https://doi.org/10.1541/ieejeiss.144.1108
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Conducting Waves Using Multi-channel Surface EMG Depends on Electrodes in Multiple Directions

Kohei Okura, Naoaki Itakura, Kazuyuki Mito, Yu Matsumoto et al.
2 citations
IEEJ Transactions on Electronics Information and Systems
Muscle activation and electromyography studies
0.37
article

Analysis of Conducting Waves Using Multi-channel Surface EMG Depends on Electrodes in Multiple Directions

Kohei Okura, Naoaki Itakura, Kazuyuki Mito, Yu Matsumoto, Tota Mizuno
article en
2 citations

Abstract

The purpose of this study is to consider the difference in the characteristics of conducting waves depending on the electrode width and direction. The electrodes proposed array electrodes that have five electrodes with widths of 10, 9, 8, 7, and 6 mm arranged in a fan shape. By incorporating a DIP switch between the electrode and the amplifier and turning it ON (short circuit), it is possible to change the electrode shape without replacing it. The analysis used the multi-channel method. As a result, when all are short-circuited, it is possible to estimate the mixing of noise in each channel. It was found that an averaged conducting wave can be obtained by widening the electrode width. In addition, from the result of more conducting waves can be extracted from the electrodes attached in the direction of the muscle fibers, it is possible to estimate the direction of the muscle fibers.

IEEJ Transactions on Electronics Information and SystemsVol. 144(11)
University of Electro-Communications (JP)
Openalex Percentile: Top 42%
Muscle activation and electromyography studies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.