Wearable Dual-Channel Transcutaneous Acupoint Electrical Stimulator Design

In recent years, as an effective means to relieve pain instead of traditional acupuncture, transcutaneous acupoint electrical stimulation has attracted much attention. In this paper, a wearable two-channel transcutaneous acupoint electrical stimulator based on STM32 is designed. The device can adjust the stimulation parameters in real time through the mobile phone APP, including the selection of stimulation channels, frequency and amplitude adjustment. The results show that the pulse width of the stimulus is 1ms, which can be adjusted in real time at the frequency of 2-100Hz and the amplitude of 0-30mA. The bipolar pulse output is supported, and the high and low frequency waveform interleaving constant current output can be achieved to ensure the stability and effectiveness of the stimulus. The wearable double-channel transcutaneous acupoint electrical stimulator designed in this paper has the advantages of high portability and intelligence, and has certain clinical and commercial value.

Authors

Institutions

Publication Details

Published
2024-08-21
DOI
https://doi.org/10.1109/iai63275.2024.10729998
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Dual-Channel Transcutaneous Acupoint Electrical Stimulator Design

Meng Li, Qing Song, Li Zhen, Mingqian Li
1 citations
Advanced Sensor and Energy Harvesting Materials
0.18
article

Wearable Dual-Channel Transcutaneous Acupoint Electrical Stimulator Design

Meng Li, Qing Song, Li Zhen, Mingqian Li
article en
1 citations

Abstract

In recent years, as an effective means to relieve pain instead of traditional acupuncture, transcutaneous acupoint electrical stimulation has attracted much attention. In this paper, a wearable two-channel transcutaneous acupoint electrical stimulator based on STM32 is designed. The device can adjust the stimulation parameters in real time through the mobile phone APP, including the selection of stimulation channels, frequency and amplitude adjustment. The results show that the pulse width of the stimulus is 1ms, which can be adjusted in real time at the frequency of 2-100Hz and the amplitude of 0-30mA. The bipolar pulse output is supported, and the high and low frequency waveform interleaving constant current output can be achieved to ensure the stability and effectiveness of the stimulus. The wearable double-channel transcutaneous acupoint electrical stimulator designed in this paper has the advantages of high portability and intelligence, and has certain clinical and commercial value.

University of Jinan (CN)
Affordable and clean energy
Openalex Percentile: Top 51%
Advanced Sensor and Energy Harvesting Materials
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.