Energy-Saving Control of Air Conditioning Water System Based on Improved NSGA-II Algorithm

The energy consumed by the HVAC system to maintain thermal comfort inside the building accounts for more than 50% of its energy consumption. The water system is the core of the HVAC system, and unreasonable control of the water system will lead to a significant amount of energy consumption. Therefore, research on energy-saving control of the water system is very important. Currently there are many optimization methods used for energy-saving control of air-conditioning water systems, but there is still a lack of research on optimization methods that ensure both indoor comfort and energy-saving effects, and most studies only focus on the control of one side of the water system. In response to the above problems, an improved non-dominant sorting genetic algorithm II (NSGA-II) method is proposed to optimize the operating parameters on both sides of chilling and cooling, so as to control both sides of the water system. The method is guided by the predicted load value, experimented on the simstore simulation platform, and compared with the fixed water supply temperature control of the air-conditioning water system and the unimproved NSGA-II algorithm control. The results show that the control strategy proposed in this paper has achieved an average energy-saving rate of 11.58% in the air-conditioning water system, and the thermal comfort has increased by 2.24%.

Authors

Institutions

Publication Details

Published
2024-08-21
DOI
https://doi.org/10.1109/iai63275.2024.10730143
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy-Saving Control of Air Conditioning Water System Based on Improved NSGA-II Algorithm

Xiangshun Li, Qiongxiang Kong, Boya Qin, Yi Liu et al.
Advanced Sensor and Control Systems
article

Energy-Saving Control of Air Conditioning Water System Based on Improved NSGA-II Algorithm

Xiangshun Li, Qiongxiang Kong, Boya Qin, Yi Liu, Huibin Li, Yangrui Gong, Xu Zhang
article en

Abstract

The energy consumed by the HVAC system to maintain thermal comfort inside the building accounts for more than 50% of its energy consumption. The water system is the core of the HVAC system, and unreasonable control of the water system will lead to a significant amount of energy consumption. Therefore, research on energy-saving control of the water system is very important. Currently there are many optimization methods used for energy-saving control of air-conditioning water systems, but there is still a lack of research on optimization methods that ensure both indoor comfort and energy-saving effects, and most studies only focus on the control of one side of the water system. In response to the above problems, an improved non-dominant sorting genetic algorithm II (NSGA-II) method is proposed to optimize the operating parameters on both sides of chilling and cooling, so as to control both sides of the water system. The method is guided by the predicted load value, experimented on the simstore simulation platform, and compared with the fixed water supply temperature control of the air-conditioning water system and the unimproved NSGA-II algorithm control. The results show that the control strategy proposed in this paper has achieved an average energy-saving rate of 11.58% in the air-conditioning water system, and the thermal comfort has increased by 2.24%.

Wuhan University of Technology (CN), China United Network Communications Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 78%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Energy-Saving Control of Air Conditioning Water System Based on Improved NSGA-II Algorithm — Xiangshun Li, Qiongxiang Kong, et al. · (2024) | TGRS Research Map | TGRS