A microsystem for in vivo wireless monitoring of plastic biliary stents using magnetoelastic sensors

With an interest in monitoring the patency of stents that are used to treat strictures in the bile duct, this paper reports the investigation of a wireless sensing system to interrogate a microsensor integrated into the stent. The microsensor is comprised of a 28-μm-thick magnetoelastic foil with 8.25-mm length and 1-mm width. Magnetic biasing is provided by permanent magnets attached to the foil. These elements are incorporated into a customized 3D polymeric package. The system electromagnetically excites the magnetoelastic resonant sensor and measures the resulting signal. Through shifts in resonant frequency and quality factor, the sensor is intended to provide an early indication of sludge accumulation in the stent. This work focuses on challenges associated with sensor miniaturization and placement, wireless range, drive signal feedthrough, and clinical use. A swine specimen in vivo experiment is described. Following endoscopic implantation of the sensor enabled plastic stent into the bile duct, at a range of approximately 17 cm, the signal-to-noise ratio of ~10<sup>6</sup> was observed with an interrogation time of 336 s. These are the first reported signals from a passive wireless magnetoelastic sensor implanted in a live animal.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2024-10-31
DOI
https://doi.org/10.1038/s41378-024-00772-8
Citations
1
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A microsystem for in vivo wireless monitoring of plastic biliary stents using magnetoelastic sensors

Richard S. Kwon, Yogesh B. Gianchandani, Scott R. Green, Ramprasad M. Nambisan et al.
1 citations
Microsystems & Nanoengineering
Gallbladder and Bile Duct Disorders
0.42
article

A microsystem for in vivo wireless monitoring of plastic biliary stents using magnetoelastic sensors

Richard S. Kwon, Yogesh B. Gianchandani, Scott R. Green, Ramprasad M. Nambisan, Grace H. Elta
article en
1 citations

Abstract

With an interest in monitoring the patency of stents that are used to treat strictures in the bile duct, this paper reports the investigation of a wireless sensing system to interrogate a microsensor integrated into the stent. The microsensor is comprised of a 28-μm-thick magnetoelastic foil with 8.25-mm length and 1-mm width. Magnetic biasing is provided by permanent magnets attached to the foil. These elements are incorporated into a customized 3D polymeric package. The system electromagnetically excites the magnetoelastic resonant sensor and measures the resulting signal. Through shifts in resonant frequency and quality factor, the sensor is intended to provide an early indication of sludge accumulation in the stent. This work focuses on challenges associated with sensor miniaturization and placement, wireless range, drive signal feedthrough, and clinical use. A swine specimen in vivo experiment is described. Following endoscopic implantation of the sensor enabled plastic stent into the bile duct, at a range of approximately 17 cm, the signal-to-noise ratio of ~10<sup>6</sup> was observed with an interrogation time of 336 s. These are the first reported signals from a passive wireless magnetoelastic sensor implanted in a live animal.

Microsystems & NanoengineeringVol. 10(1)
University of Michigan (US), Integrated Sensors (United States) (US), Michigan Medicine (US), Integrated Sensing Systems (United States) (US)
National Institutes of Health
Openalex Percentile: Top 31%
Gallbladder and Bile Duct Disorders
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.