Reconstruction of a complex-valued object without a support constraint

This study demonstrates that a nonnegative complex-valued object without support constraints can be reconstructed from its diffraction pattern, even with partially missing data. We employed a continuous hybrid input-output (CHIO) algorithm, which imposes double nonnegative constraints on the real and imaginary parts of the object. The missing data at the diffraction pattern center is recovered linearly before iterations. Simulations and experiments indicate that this method yields more accurate results and lower reconstruction errors than the hybrid input-output (HIO) algorithm, thus offering a robust approach for coherent diffraction microscopy of biological samples using soft x rays or visible light lasers.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2024-10-31
DOI
https://doi.org/10.1364/ol.541058
Citations
1
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconstruction of a complex-valued object without a support constraint

Mengxin Liu, Guangxu Liu, Meng Shen, Wenke Cao et al.
1 citations
Optics Letters
Advanced X-ray Imaging Techniques
0.61
article

Reconstruction of a complex-valued object without a support constraint

Mengxin Liu, Guangxu Liu, Meng Shen, Wenke Cao, Shengjie Ma, Jiacheng Li, Jian Zhang, Jiaxu Chen, Yuli Huang
article en
1 citations

Abstract

This study demonstrates that a nonnegative complex-valued object without support constraints can be reconstructed from its diffraction pattern, even with partially missing data. We employed a continuous hybrid input-output (CHIO) algorithm, which imposes double nonnegative constraints on the real and imaginary parts of the object. The missing data at the diffraction pattern center is recovered linearly before iterations. Simulations and experiments indicate that this method yields more accurate results and lower reconstruction errors than the hybrid input-output (HIO) algorithm, thus offering a robust approach for coherent diffraction microscopy of biological samples using soft x rays or visible light lasers.

Optics LettersVol. 49(23)
Shandong Jianzhu University (CN)
Shandong Jianzhu University
Openalex Percentile: Top 29%
Advanced X-ray Imaging Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.