Diagnostics of porcelain insulators by partial discharges characteristics

RELEVANCE of the research is in the development of a non-destructive method for diagnosing porcelain insulators of high-voltage electrical equipment based on analysis of the characteristics of partial discharges (PDs). The problem of the final stage of breakdown of both the discharge gap and porcelain insulators recognizing is currently has not solved. THE PURPOSE. Recognition of PDs in solid insulation, study of PDs characteristics in a pre- breakdown situation, recognition of defective insulators based on PDs characteristics analysing. METHODS. The study of PDs characteristics for a defective and functional porcelain insulator were carried out. To study the characteristics of various types of PDs, including in the pre-breakdown situation, a system of surface-needle electrode system was used. RESULTS. The article describes compares the PDs characteristics obtained using standard R-400 device and a digital storage oscilloscope (DSO) using a telescopic antenna. A technique for recognizing the development of the pre-breakdown situation of the surface-needle discharge gap and the porcelain insulator was developed. The technique for recognizing a defective porcelain insulator from the amplitude-phase diagrams (APD) of PDs was developed. The method for assessing the breakdown voltage of porcelain insulators based on the characteristics of partial discharges was developed. CONCLUSION. At the moment of transition to the pre-breakdown stage were observed a sharp increase in the counter-movement of charges of opposite polarity. In the stage immediately before the breakdown, near zero values of the applied voltage of negative polarity, ordered PDs of the same polarity as the applied voltage were recorded in large numbers. These discharges led to an increase in leakage current and were interpreted as initial corona discharges. These discharges were recorded both by a telescopic antenna in a surface-needle system and in porcelain insulators.

Authors

Institutions

Publication Details

Journal
Power engineering research equipment technology
Published
2024-10-28
DOI
https://doi.org/10.30724/1998-9903-2024-26-5-19-30
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostics of porcelain insulators by partial discharges characteristics

Yu. V. Piskovatskiy, A. S. Minkin, А. Н. Гавриленко, A. M. Gataullin
Power engineering research equipment technology
High voltage insulation and dielectric phenomena
article

Diagnostics of porcelain insulators by partial discharges characteristics

Yu. V. Piskovatskiy, A. S. Minkin, А. Н. Гавриленко, A. M. Gataullin
article en

Abstract

RELEVANCE of the research is in the development of a non-destructive method for diagnosing porcelain insulators of high-voltage electrical equipment based on analysis of the characteristics of partial discharges (PDs). The problem of the final stage of breakdown of both the discharge gap and porcelain insulators recognizing is currently has not solved. THE PURPOSE. Recognition of PDs in solid insulation, study of PDs characteristics in a pre- breakdown situation, recognition of defective insulators based on PDs characteristics analysing. METHODS. The study of PDs characteristics for a defective and functional porcelain insulator were carried out. To study the characteristics of various types of PDs, including in the pre-breakdown situation, a system of surface-needle electrode system was used. RESULTS. The article describes compares the PDs characteristics obtained using standard R-400 device and a digital storage oscilloscope (DSO) using a telescopic antenna. A technique for recognizing the development of the pre-breakdown situation of the surface-needle discharge gap and the porcelain insulator was developed. The technique for recognizing a defective porcelain insulator from the amplitude-phase diagrams (APD) of PDs was developed. The method for assessing the breakdown voltage of porcelain insulators based on the characteristics of partial discharges was developed. CONCLUSION. At the moment of transition to the pre-breakdown stage were observed a sharp increase in the counter-movement of charges of opposite polarity. In the stage immediately before the breakdown, near zero values of the applied voltage of negative polarity, ordered PDs of the same polarity as the applied voltage were recorded in large numbers. These discharges led to an increase in leakage current and were interpreted as initial corona discharges. These discharges were recorded both by a telescopic antenna in a surface-needle system and in porcelain insulators.

Power engineering research equipment technologyVol. 26(5)
Kazan State Power Engineering University (RU)
Affordable and clean energy
Openalex Percentile: Top 88%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.