Trace Detection of Pb(II) using Square Wave Anodic Stripping Voltammetry with Stainless Steel Electrodes

<p>Lead (Pb(II)) is well known as a dangerous environmental contaminant that harms public health worldwide. Early Pb(II) detection before release into the water system is important. This work describes an inexpensive Pb(II) determination using 5 mm diameter stainless steel rod type 304 as a working electrode. Using a batch system, the research employed 10 mL of 0.1 M acetate buffer at pH 4.5. The best operation was at a deposition potential of -1.2V for 300 s. It provides a linear range in the concentration range of 0.075 – 1 µg/mL Pb(II) (r = 0.994). The limit of detection (LOD) and limit of quantification (LOQ) of Pb(II) were at 0.057 µg/mL and 0.189 µg/mL, respectively. Repeatability and reproducibility were expressed in the relative standard deviation range of 1.26-3.71% in the testing a Pb(II) concentration range of 0.2-1.0 µg/mL and 5.32% in testing a Pb(II) concentration of 0.4 µg/mL. A very low-cost stainless-steel electrode proposed a high operational stability up to 10 measurements with RSD of 4.39%.</p>

Authors

Institutions

Publication Details

Journal
ALCHEMY Jurnal Penelitian Kimia
Published
2024-09-30
DOI
https://doi.org/10.20961/alchemy.20.2.84859.238-246
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trace Detection of Pb(II) using Square Wave Anodic Stripping Voltammetry with Stainless Steel Electrodes

Muhammad Zamhari, Tawatchai Kangkamano, Sendika Harrista, Adinda Fara Aulia et al.
ALCHEMY Jurnal Penelitian Kimia
Electrochemical Analysis and Applications
article

Trace Detection of Pb(II) using Square Wave Anodic Stripping Voltammetry with Stainless Steel Electrodes

Muhammad Zamhari, Tawatchai Kangkamano, Sendika Harrista, Adinda Fara Aulia, Safina Nur Faizah
article en

Abstract

<p>Lead (Pb(II)) is well known as a dangerous environmental contaminant that harms public health worldwide. Early Pb(II) detection before release into the water system is important. This work describes an inexpensive Pb(II) determination using 5 mm diameter stainless steel rod type 304 as a working electrode. Using a batch system, the research employed 10 mL of 0.1 M acetate buffer at pH 4.5. The best operation was at a deposition potential of -1.2V for 300 s. It provides a linear range in the concentration range of 0.075 – 1 µg/mL Pb(II) (r = 0.994). The limit of detection (LOD) and limit of quantification (LOQ) of Pb(II) were at 0.057 µg/mL and 0.189 µg/mL, respectively. Repeatability and reproducibility were expressed in the relative standard deviation range of 1.26-3.71% in the testing a Pb(II) concentration range of 0.2-1.0 µg/mL and 5.32% in testing a Pb(II) concentration of 0.4 µg/mL. A very low-cost stainless-steel electrode proposed a high operational stability up to 10 measurements with RSD of 4.39%.</p>

ALCHEMY Jurnal Penelitian KimiaVol. 20(2)
Sunan Kalijaga State Islamic University Yogyakarta (ID), Songkhla Rajabhat University (TH), Thaksin University (TH)
Openalex Percentile: Top 84%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Trace Detection of Pb(II) using Square Wave Anodic Stripping Voltammetry with Stainless Steel Electrodes — Muhammad Zamhari, Tawatchai Kangkamano, et al. · ALCHEMY Jurnal Penelitian Kimia (2024) | TGRS Research Map | TGRS