10 years follow up of immediately loaded implant assisted complete mandibular overdenture

During treatment Increased implant stability implies successful osseointegration with the surrounding bone whatever diminished implant stability may diagnose a type of implantation failure. So, it is essential to evaluate the implant stability quantitatively during the treatment procedure. Peri-implantitis is characterized by clinical signs of inflammation such as increased probing depths, and bone resorption, leading to implant failure. In peri-implantitis, Changes the biofilm structure towards increased counts of pathogenic microorganisms such as Porphyromonas gingivalis, which is one of the bacteria with the highest virulence. Aim: clinical evaluation of immediately loaded implant assisted complete mandibular overdenture after 10 years follow up regarding implant stability, periimplant pocket depth measurement and microbial evaluation of Porphyromonas gingivalis M&M: 5 completely edentulous male patients with maxillary conventional complete denture, and mandibular immediate loaded implant assisted complete overdenture using two implants in areas of mandibular canines with diameter 3.6 mm width and length 10 mm with O-ring attachments for retaining the overdenture, These patients were evaluated regarding dental implant stability using Osstell ISQ, clinical measurement of periimplant pocket depth (PPD) and microbial evaluation of Porphyromonas gingivalis (Pg). Results: After 10 years of implants placement, there was non-significant increase in ISQ of the dental implants compared to baseline readings but there was significant increase of PPD and finally non-significant increase level of Porphyromonas gingivalis. Con.: Two immediately loaded dental implants with 10mm length and 3.6mm diameter are satisfactory to assist complete mandibular overdenture opposed by conventional maxillary complete denture.

Authors

Institutions

Publication Details

Journal
Egyptian Journal of Oral & Maxillofacial Surgery
Published
2024-10-01
DOI
https://doi.org/10.21608/omx.2024.325600.1268
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

10 years follow up of immediately loaded implant assisted complete mandibular overdenture

Hesham Borg, Mona Al Ahmady El Meligy, Mohammed Elkafrawy
Egyptian Journal of Oral & Maxillofacial Surgery
Dental Implant Techniques and Outcomes
article

10 years follow up of immediately loaded implant assisted complete mandibular overdenture

Hesham Borg, Mona Al Ahmady El Meligy, Mohammed Elkafrawy
article en

Abstract

During treatment Increased implant stability implies successful osseointegration with the surrounding bone whatever diminished implant stability may diagnose a type of implantation failure. So, it is essential to evaluate the implant stability quantitatively during the treatment procedure. Peri-implantitis is characterized by clinical signs of inflammation such as increased probing depths, and bone resorption, leading to implant failure. In peri-implantitis, Changes the biofilm structure towards increased counts of pathogenic microorganisms such as Porphyromonas gingivalis, which is one of the bacteria with the highest virulence. Aim: clinical evaluation of immediately loaded implant assisted complete mandibular overdenture after 10 years follow up regarding implant stability, periimplant pocket depth measurement and microbial evaluation of Porphyromonas gingivalis M&M: 5 completely edentulous male patients with maxillary conventional complete denture, and mandibular immediate loaded implant assisted complete overdenture using two implants in areas of mandibular canines with diameter 3.6 mm width and length 10 mm with O-ring attachments for retaining the overdenture, These patients were evaluated regarding dental implant stability using Osstell ISQ, clinical measurement of periimplant pocket depth (PPD) and microbial evaluation of Porphyromonas gingivalis (Pg). Results: After 10 years of implants placement, there was non-significant increase in ISQ of the dental implants compared to baseline readings but there was significant increase of PPD and finally non-significant increase level of Porphyromonas gingivalis. Con.: Two immediately loaded dental implants with 10mm length and 3.6mm diameter are satisfactory to assist complete mandibular overdenture opposed by conventional maxillary complete denture.

Egyptian Journal of Oral & Maxillofacial SurgeryVol. 15(4)
Tanta University (EG), Salam University (AF)
Gender equality
Openalex Percentile: Top 71%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.