Impedance and electrically evoked compound action potential (ECAP) changes overtime in patients with cochlear implants

Background: Cochlear implantation referred to as the treatment of choice for hearing rehabilitation in patients with bilateral severe to profound sensorineural hearing loss that is no longer responsive to amplification . The integrity of this CI can be assessed intraoperatively and postoperatively through objective measures which include telemetric measurement of electrode impedance and electrically evoked compound action potential. Aim of the work: To compare electrode impedance values and electrically evoked compound action potential (ECAP) thresholds intraoperatively and postoperatively to asses whether significant changes take place overtime or not.Patient and Methods This study was carried on 25 subjects with age ranging from (3-60) yrs. 21 of the subjects were implanted unilaterally with a MED-EL devices and 4 implanted with cochlear devices. Impedance values and ECAP thresholds were monitored at the time of surgery then postoperatively at 1st day tunning, 1 month, 2 months and 6th months after 1st day tunning.Results: Intraoperative impedance value was the lowest among all readings measured in all electrodes. The highest value was measured at the 1st day tunning after surgery, after which impedance value continued to decrease significantly when compared to the 1st day tunning. ECAP thresholds showed the highest value intraoperatively after which the ECAP continued to decrease. However, the difference between readings was statistically nonsignificant.Conclusion: During surgery, telemetry provides valuable information regarding integrity of electrodes, the electrical output of the implant and the response of the auditory system to electrical stimulation; however, it is not a valuable predictor of post-operative performance.

Authors

Institutions

Publication Details

Journal
Ain Shams Medical Journal
Published
2024-10-24
DOI
https://doi.org/10.21608/asmj.2023.226997.1146
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedance and electrically evoked compound action potential (ECAP) changes overtime in patients with cochlear implants

Tayseer Taha Abdel Rahman, Adel Abdel Maksoud Nassar, Ghada Moharram, Sara Abdallah Tawfeek
Ain Shams Medical Journal
Hearing Loss and Rehabilitation
article

Impedance and electrically evoked compound action potential (ECAP) changes overtime in patients with cochlear implants

Tayseer Taha Abdel Rahman, Adel Abdel Maksoud Nassar, Ghada Moharram, Sara Abdallah Tawfeek
article en

Abstract

Background: Cochlear implantation referred to as the treatment of choice for hearing rehabilitation in patients with bilateral severe to profound sensorineural hearing loss that is no longer responsive to amplification . The integrity of this CI can be assessed intraoperatively and postoperatively through objective measures which include telemetric measurement of electrode impedance and electrically evoked compound action potential. Aim of the work: To compare electrode impedance values and electrically evoked compound action potential (ECAP) thresholds intraoperatively and postoperatively to asses whether significant changes take place overtime or not.Patient and Methods This study was carried on 25 subjects with age ranging from (3-60) yrs. 21 of the subjects were implanted unilaterally with a MED-EL devices and 4 implanted with cochlear devices. Impedance values and ECAP thresholds were monitored at the time of surgery then postoperatively at 1st day tunning, 1 month, 2 months and 6th months after 1st day tunning.Results: Intraoperative impedance value was the lowest among all readings measured in all electrodes. The highest value was measured at the 1st day tunning after surgery, after which impedance value continued to decrease significantly when compared to the 1st day tunning. ECAP thresholds showed the highest value intraoperatively after which the ECAP continued to decrease. However, the difference between readings was statistically nonsignificant.Conclusion: During surgery, telemetry provides valuable information regarding integrity of electrodes, the electrical output of the implant and the response of the auditory system to electrical stimulation; however, it is not a valuable predictor of post-operative performance.

Ain Shams Medical JournalVol. 0(0)
Ain Shams University (EG)
Openalex Percentile: Top 80%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.