Development and performance evaluation of a thin GAGG:Ce scintillator plate for high resolution synchrotron radiation X-ray imaging

Abstract Scintillator-based X-ray imaging detectors are pivotal in numerous scientific and practical domains, including medical imaging, food and device inspection, and security monitoring. Recent advancements have spurred interest in 4D X-ray imaging using synchrotron radiation, necessitating higher temporal resolutions. Consequently, this places stringent demands on X-ray detector technology, especially when X-ray energy exceeds 20 keV. The selection of a suitable scintillator material is crucial for achieving optimal timing resolution, yet it poses a significant challenge in dynamic X-ray imaging. This study delves into the optimization of scintillator properties and their impact on spatial resolution and light output, elucidating the performance of Ce-doped Gd 3 Ga 3 Al 2 O 12 (GAGG:Ce) scintillators for X-ray imaging applications. We developed a micro X-ray imaging detector using a 100 μm-thick GAGG:Ce scintillator plate and conducted X-ray imaging tests at the Aichi SR facility. The results demonstrated that the resolution, quantified as the chart slit width at a contrast transfer function (CTF) value of 10%, reached 2 ∼ 3 μm with a 4× lens, 0.52 μm± 0.03 μm with a 20× lens, and 0.42 μm± 0.01 μm with a 40× lens. Although the results of this study did not achieve a spatial resolution nearing the effective pixel size of the 40× lens, the text also elucidates the underlying reasons for this limitation. Furthermore, we compared the X-ray sensitivity of our GAGG:Ce scintillator plate with that of a commercial LuAG:Ce scintillator, revealing an approximately 1.5-fold increase in light output. As a demonstration, transmission images of dried small fish were captured using the GAGG:Ce scintillator plate and the developed X-ray imaging system. These findings highlight the potential of the X-ray imaging detector devised in this study for future generations of X-ray imaging applications.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-10-01
DOI
https://doi.org/10.1088/1748-0221/19/10/p10030
Citations
5
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and performance evaluation of a thin GAGG:Ce scintillator plate for high resolution synchrotron radiation X-ray imaging

Katsunori Yogo, Kohei Nakanishi, Masao Yoshino, Kei Kamada et al.
5 citations
Journal of Instrumentation
Radiation Detection and Scintillator Technologies
3.04
article

Development and performance evaluation of a thin GAGG:Ce scintillator plate for high resolution synchrotron radiation X-ray imaging

Katsunori Yogo, Kohei Nakanishi, Masao Yoshino, Kei Kamada, N. Koshikawa, J. Kataoka, Seiichi Yamamoto, Akira Yoshikawa
article en
5 citations

Abstract

Abstract Scintillator-based X-ray imaging detectors are pivotal in numerous scientific and practical domains, including medical imaging, food and device inspection, and security monitoring. Recent advancements have spurred interest in 4D X-ray imaging using synchrotron radiation, necessitating higher temporal resolutions. Consequently, this places stringent demands on X-ray detector technology, especially when X-ray energy exceeds 20 keV. The selection of a suitable scintillator material is crucial for achieving optimal timing resolution, yet it poses a significant challenge in dynamic X-ray imaging. This study delves into the optimization of scintillator properties and their impact on spatial resolution and light output, elucidating the performance of Ce-doped Gd 3 Ga 3 Al 2 O 12 (GAGG:Ce) scintillators for X-ray imaging applications. We developed a micro X-ray imaging detector using a 100 μm-thick GAGG:Ce scintillator plate and conducted X-ray imaging tests at the Aichi SR facility. The results demonstrated that the resolution, quantified as the chart slit width at a contrast transfer function (CTF) value of 10%, reached 2 ∼ 3 μm with a 4× lens, 0.52 μm± 0.03 μm with a 20× lens, and 0.42 μm± 0.01 μm with a 40× lens. Although the results of this study did not achieve a spatial resolution nearing the effective pixel size of the 40× lens, the text also elucidates the underlying reasons for this limitation. Furthermore, we compared the X-ray sensitivity of our GAGG:Ce scintillator plate with that of a commercial LuAG:Ce scintillator, revealing an approximately 1.5-fold increase in light output. As a demonstration, transmission images of dried small fish were captured using the GAGG:Ce scintillator plate and the developed X-ray imaging system. These findings highlight the potential of the X-ray imaging detector devised in this study for future generations of X-ray imaging applications.

Journal of InstrumentationVol. 19(10)
Waseda University (JP), Tohoku University (JP), Nagoya University (JP)
Openalex Percentile: Top 9%
Radiation Detection and Scintillator Technologies
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.