Application of Ortho-Bridge System after Femoral Bone Transport

The bone transport technique uses the principle of distraction-osteogenesis and fill bone defects with the aid of an external fixator. In order to evaluate the clinical effect of femoral internal fixation with Ortho-Bridge System after bone transport, 4 patients after femoral bone transport from October 2020 to October 2022 are studied in this paper. Among them, 3 patients ran refracture of femur after removal of the Limb reconstruction system, 1 patient just finish femoral bone transport and request internal fixation. The surgery results show that Ortho-Bridge System can be used in the situation that conventional Locking compression plate and intramedullary nail are not suitable due to anatomical variation after femoral bone transport. Key words: femoral fracture; Ortho-Bridge System; bone transport; postoperative complications of bone transport.

Authors

Institutions

Publication Details

Journal
Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca
Published
2024-10-21
DOI
https://doi.org/10.55095/achot2024/043
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Ortho-Bridge System after Femoral Bone Transport

Wenjun Zhu, Shuo Liu, Jin‐Shui Yang, Qin Xu et al.
Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca
Orthopaedic implants and arthroplasty
article

Application of Ortho-Bridge System after Femoral Bone Transport

Wenjun Zhu, Shuo Liu, Jin‐Shui Yang, Qin Xu, Jianyi Xiong, Lijun Liu, Z. Q. Fu
article en

Abstract

The bone transport technique uses the principle of distraction-osteogenesis and fill bone defects with the aid of an external fixator. In order to evaluate the clinical effect of femoral internal fixation with Ortho-Bridge System after bone transport, 4 patients after femoral bone transport from October 2020 to October 2022 are studied in this paper. Among them, 3 patients ran refracture of femur after removal of the Limb reconstruction system, 1 patient just finish femoral bone transport and request internal fixation. The surgery results show that Ortho-Bridge System can be used in the situation that conventional Locking compression plate and intramedullary nail are not suitable due to anatomical variation after femoral bone transport. Key words: femoral fracture; Ortho-Bridge System; bone transport; postoperative complications of bone transport.

Acta chirurgiae orthopaedicae et traumatologiae CechoslovacaVol. 91(5)
First Affiliated Hospital of Guangdong Pharmaceutical University (CN)
Openalex Percentile: Top 64%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of Ortho-Bridge System after Femoral Bone Transport — Wenjun Zhu, Shuo Liu, et al. · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca (2024) | TGRS Research Map | TGRS