Analysis of Charging Methods for Inner Mongolia Power Grid 220kV System

This article combines the 220kV system of the 500kV substation in the main grid of Inner Mongolia Grid to explore the busbar structure and common dead zone faults of the 220kV system. The faults are removed through bus differential protection and failure protection. The analysis focuses on the need to charge the equipment before operation due to infrastructure, production, and other projects. This article discusses the characteristics of two charging methods, and proposes that for the charging of new equipment, the charging method based on the protection device's logic of charging to the dead zone should be selected to reduce the scope of removal, avoid potential hazards, and ensure the stable and reliable operation of the power grid. Through simulation experiments, the charging method based on the dead zone logic of the bus differential protection can accurately isolate faults without expanding the power outage area, significantly enhancing the reliability of the power grid.

Authors

Institutions

Publication Details

Published
2024-08-29
DOI
https://doi.org/10.1109/neessc62857.2024.10733506
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Charging Methods for Inner Mongolia Power Grid 220kV System

X.Y. Wei, Honggang Xie
Power Systems and Technologies
article

Analysis of Charging Methods for Inner Mongolia Power Grid 220kV System

X.Y. Wei, Honggang Xie
article en

Abstract

This article combines the 220kV system of the 500kV substation in the main grid of Inner Mongolia Grid to explore the busbar structure and common dead zone faults of the 220kV system. The faults are removed through bus differential protection and failure protection. The analysis focuses on the need to charge the equipment before operation due to infrastructure, production, and other projects. This article discusses the characteristics of two charging methods, and proposes that for the charging of new equipment, the charging method based on the protection device's logic of charging to the dead zone should be selected to reduce the scope of removal, avoid potential hazards, and ensure the stable and reliable operation of the power grid. Through simulation experiments, the charging method based on the dead zone logic of the bus differential protection can accurately isolate faults without expanding the power outage area, significantly enhancing the reliability of the power grid.

Inner Mongolia Electric Power (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 83%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.