A comprehensive head-to-head comparison of key plasma phosphorylated tau 217 biomarker tests

Plasma phosphorylated-tau 217 (p-tau217) is currently the most promising biomarker for reliable detection of Alzheimer's disease pathology. Various p-tau217 assays have been developed, but their relative performance is unclear. We compared key plasma p-tau217 tests using cross-sectional and longitudinal measures of amyloid-β (Aβ)-PET, tau-PET and cognition as outcomes and benchmarked them against CSF biomarker tests. Samples from 998 individuals [mean (range) age 68.5 (20.0-92.5) years, 53% female] from the Swedish BioFINDER-2 cohort, including both cognitively unimpaired and cognitively impaired individuals, were analysed. Plasma p-tau217 was measured with mass spectrometry assays [the ratio between phosphorylated and non-phosphorylated (%p-tau217WashU) and p-tau217WashU] and with immunoassays (p-tau217Lilly, p-tau217Janssen and p-tau217ALZpath). CSF biomarkers included p-tau217Lilly, the US Food and Drug Administration-approved p-tau181/Aβ42Elecsys, and p-tau181Elecsys. All plasma p-tau217 tests exhibited a high ability to detect abnormal Aβ-PET [area under the curve (AUC) range: 0.91-0.96] and tau-PET (AUC range: 0.94-0.97). Plasma %p-tau217WashU had the highest performance, with significantly higher AUCs than all the immunoassays (Pdiff < 0.007). For detecting Aβ-PET status, %p-tau217WashU had an accuracy of 0.93 (immunoassays: 0.83-0.88), sensitivity of 0.91 (immunoassays: 0.84-0.87) and a specificity of 0.94 (immunoassays: 0.85-0.89). Among immunoassays, p-tau217Lilly and plasma p-tau217ALZpath had higher AUCs than plasma p-tau217Janssen for Aβ-PET status (Pdiff < 0.006), and p-tau217Lilly outperformed plasma p-tau217ALZpath for tau-PET status (Pdiff = 0.025). Plasma %p-tau217WashU exhibited stronger associations with all PET load outcomes compared with immunoassays; baseline Aβ-PET load (R2: 0.72; immunoassays: 0.47-0.58; Pdiff < 0.001), baseline tau-PET load (R2: 0.51; immunoassays: 0.38-0.45; Pdiff < 0.001), longitudinal Aβ-PET load (R2: 0.53; immunoassays: 0.31-0.38; Pdiff < 0.001) and longitudinal tau-PET load (R2: 0.50; immunoassays: 0.35-0.43; Pdiff < 0.014). Among immunoassays, plasma p-tau217Lilly was more associated with Aβ-PET load than plasma p-tau217Janssen (Pdiff < 0.020) and with tau-PET load than both plasma p-tau217Janssen and plasma p-tau217ALZpath (all Pdiff < 0.010). Plasma %p-tau217 also correlated more strongly with baseline cognition (Mini-Mental State Examination) than all immunoassays (R2: %p-tau217WashU: 0.33; immunoassays: 0.27-0.30; Pdiff < 0.024). The main results were replicated in an external cohort from Washington University in St Louis (n = 219). Finally, p-tau217NULISA showed similar performance to other immunoassays in subsets of both cohorts. In summary, both mass spectrometry- and immunoassay-based p-tau217 tests generally perform well in identifying Aβ-PET, tau-PET and cognitive abnormalities, but %p-tau217WashU performed significantly better than all the examined immunoassays. Plasma %p-tau217 may be considered as a stand-alone confirmatory test for Alzheimer's disease pathology, whereas some immunoassays might be better suited as triage tests where positive results are confirmed with a second test, which needs to be determined by future reviews incorporating results from multiple cohorts.

Authors

Institutions

Publication Details

Journal
Brain
Published
2024-10-26
DOI
https://doi.org/10.1093/brain/awae346
Citations
75
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
28.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comprehensive head-to-head comparison of key plasma phosphorylated tau 217 biomarker tests

Tammie L.S. Benzinger, Nicholas James Ashton, Alexa Pichet Binette, Divya Bali et al.
75 citations
Brain
Dementia and Cognitive Impairment Research
28.92
article

A comprehensive head-to-head comparison of key plasma phosphorylated tau 217 biomarker tests

Tammie L.S. Benzinger, Nicholas James Ashton, Alexa Pichet Binette, Divya Bali, Randall John Bateman, Kaj Blennow, Carlos Cruchaga, Niklas Mattsson, Burak Arslan, Anna Orduña Dolado, Oskar Hansson, Gemma Salvadó, Cyrus A. Raji, Gallen Triana‐Baltzer, Nicolas R. Barthélemy, Hartmuth C. Kolb, Laura Ibáñez, Suzanne E. Schindler, Henrik Zetterberg, Andrew J. Aschenbrenner, Noëlle Warmenhoven, Jigyasha Timsina, Shorena Janelidze
article en
75 citations

Abstract

Plasma phosphorylated-tau 217 (p-tau217) is currently the most promising biomarker for reliable detection of Alzheimer's disease pathology. Various p-tau217 assays have been developed, but their relative performance is unclear. We compared key plasma p-tau217 tests using cross-sectional and longitudinal measures of amyloid-β (Aβ)-PET, tau-PET and cognition as outcomes and benchmarked them against CSF biomarker tests. Samples from 998 individuals [mean (range) age 68.5 (20.0-92.5) years, 53% female] from the Swedish BioFINDER-2 cohort, including both cognitively unimpaired and cognitively impaired individuals, were analysed. Plasma p-tau217 was measured with mass spectrometry assays [the ratio between phosphorylated and non-phosphorylated (%p-tau217WashU) and p-tau217WashU] and with immunoassays (p-tau217Lilly, p-tau217Janssen and p-tau217ALZpath). CSF biomarkers included p-tau217Lilly, the US Food and Drug Administration-approved p-tau181/Aβ42Elecsys, and p-tau181Elecsys. All plasma p-tau217 tests exhibited a high ability to detect abnormal Aβ-PET [area under the curve (AUC) range: 0.91-0.96] and tau-PET (AUC range: 0.94-0.97). Plasma %p-tau217WashU had the highest performance, with significantly higher AUCs than all the immunoassays (Pdiff < 0.007). For detecting Aβ-PET status, %p-tau217WashU had an accuracy of 0.93 (immunoassays: 0.83-0.88), sensitivity of 0.91 (immunoassays: 0.84-0.87) and a specificity of 0.94 (immunoassays: 0.85-0.89). Among immunoassays, p-tau217Lilly and plasma p-tau217ALZpath had higher AUCs than plasma p-tau217Janssen for Aβ-PET status (Pdiff < 0.006), and p-tau217Lilly outperformed plasma p-tau217ALZpath for tau-PET status (Pdiff = 0.025). Plasma %p-tau217WashU exhibited stronger associations with all PET load outcomes compared with immunoassays; baseline Aβ-PET load (R2: 0.72; immunoassays: 0.47-0.58; Pdiff < 0.001), baseline tau-PET load (R2: 0.51; immunoassays: 0.38-0.45; Pdiff < 0.001), longitudinal Aβ-PET load (R2: 0.53; immunoassays: 0.31-0.38; Pdiff < 0.001) and longitudinal tau-PET load (R2: 0.50; immunoassays: 0.35-0.43; Pdiff < 0.014). Among immunoassays, plasma p-tau217Lilly was more associated with Aβ-PET load than plasma p-tau217Janssen (Pdiff < 0.020) and with tau-PET load than both plasma p-tau217Janssen and plasma p-tau217ALZpath (all Pdiff < 0.010). Plasma %p-tau217 also correlated more strongly with baseline cognition (Mini-Mental State Examination) than all immunoassays (R2: %p-tau217WashU: 0.33; immunoassays: 0.27-0.30; Pdiff < 0.024). The main results were replicated in an external cohort from Washington University in St Louis (n = 219). Finally, p-tau217NULISA showed similar performance to other immunoassays in subsets of both cohorts. In summary, both mass spectrometry- and immunoassay-based p-tau217 tests generally perform well in identifying Aβ-PET, tau-PET and cognitive abnormalities, but %p-tau217WashU performed significantly better than all the examined immunoassays. Plasma %p-tau217 may be considered as a stand-alone confirmatory test for Alzheimer's disease pathology, whereas some immunoassays might be better suited as triage tests where positive results are confirmed with a second test, which needs to be determined by future reviews incorporating results from multiple cohorts.

BrainVol. 148(2)
Johnson & Johnson (United States) (US), University of Wisconsin–Madison (US), Malmö University (SE), King's College London (GB), Lund University (SE), South London and Maudsley NHS Foundation Trust (GB), Washington University in St. Louis (US), Stavanger University Hospital (NO), Hong Kong Science and Technology Parks Corporation (HK), Sahlgrenska University Hospital (SE), Centre for Mental Health (GB), Hope Center for Neurological Disorders (US), Wallenberg Wood Science Center (SE), UK Dementia Research Institute (GB), Skåne University Hospital (SE), National Hospital for Neurology and Neurosurgery (GB), University College London (GB), University of Gothenburg (SE)
Good health and well-being
Openalex Percentile: Top 0%
Dementia and Cognitive Impairment Research
28.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.