[Design of a Conformal Ablation System Based on Independent Control of Radiofrequency Electrode Arrays].

This study aims to develop an independent control system for radiofrequency electrode arrays, intended for the conformal ablation of unwanted tissues. Unlike traditional single radiofrequency voltage applications, this study employs high-frequency transformer isolation and radiofrequency load matching technologies to divide the radiofrequency signal source into eight independent groups. Each group operates at the same phase and frequency but with different voltage values. Experimental results indicate that the designed system can independently output various combinations of radiofrequency signals. The actual output voltage has a relative error controlled within 6%, the frequency error is less than 0.5%, and the phase difference among the groups is less than 1°. In the biomimetic tissue heating experiments, it is found that by controlling the voltage of each electrode within the electrode array, ablation of different shapes can be achieved, and the ablation depth is positively correlated with the applied radiofrequency voltage.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-09-30
DOI
https://doi.org/10.12455/j.issn.1671-7104.240171
Primary Topic
Laser Design and Applications
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Design of a Conformal Ablation System Based on Independent Control of Radiofrequency Electrode Arrays].

Jincheng Zou, Aili Zhang
PubMed
Laser Design and Applications
article

[Design of a Conformal Ablation System Based on Independent Control of Radiofrequency Electrode Arrays].

Jincheng Zou, Aili Zhang
article en

Abstract

This study aims to develop an independent control system for radiofrequency electrode arrays, intended for the conformal ablation of unwanted tissues. Unlike traditional single radiofrequency voltage applications, this study employs high-frequency transformer isolation and radiofrequency load matching technologies to divide the radiofrequency signal source into eight independent groups. Each group operates at the same phase and frequency but with different voltage values. Experimental results indicate that the designed system can independently output various combinations of radiofrequency signals. The actual output voltage has a relative error controlled within 6%, the frequency error is less than 0.5%, and the phase difference among the groups is less than 1°. In the biomimetic tissue heating experiments, it is found that by controlling the voltage of each electrode within the electrode array, ablation of different shapes can be achieved, and the ablation depth is positively correlated with the applied radiofrequency voltage.

PubMedVol. 48(5)
Shanghai Jiao Tong University (CN)
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.