[Research on Test Method of Active Medical Device Preset Service Life Evaluation].

When applying for registration of an active medical device, it is necessary to submit research and verification data regarding the device's service life. This study primarily proposes how to verify and evaluate the preset service life of active medical devices through reliability testing. Initially, the definition of the product's service life is introduced. Subsequently, the determination of the test sample size, the type and magnitude of the test stress, the conventional test duration, the accelerated test duration, and the evaluation of the service life of the active medical device based on the test results are elucidated. Finally, an example of evaluating the service life of a non-invasive ventilator is provided for further illustration. This study offers a comprehensive closed-loop process for verifying and evaluating the preset service life of active medical devices using the test method, providing a scientific, reasonable, practical, and exhaustive test evaluation approach for enterprises and regulatory agencies. This has broad significance for universal dissemination and aids enterprises and testing institutions in conducting pertinent research and verification tasks.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2024-09-30
DOI
https://doi.org/10.12455/j.issn.1671-7104.240046
Primary Topic
Quality and Safety in Healthcare
Type
article
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[Research on Test Method of Active Medical Device Preset Service Life Evaluation].

Fei He, Weiming Wang
PubMed
Quality and Safety in Healthcare
article

[Research on Test Method of Active Medical Device Preset Service Life Evaluation].

Fei He, Weiming Wang
article en

Abstract

When applying for registration of an active medical device, it is necessary to submit research and verification data regarding the device's service life. This study primarily proposes how to verify and evaluate the preset service life of active medical devices through reliability testing. Initially, the definition of the product's service life is introduced. Subsequently, the determination of the test sample size, the type and magnitude of the test stress, the conventional test duration, the accelerated test duration, and the evaluation of the service life of the active medical device based on the test results are elucidated. Finally, an example of evaluating the service life of a non-invasive ventilator is provided for further illustration. This study offers a comprehensive closed-loop process for verifying and evaluating the preset service life of active medical devices using the test method, providing a scientific, reasonable, practical, and exhaustive test evaluation approach for enterprises and regulatory agencies. This has broad significance for universal dissemination and aids enterprises and testing institutions in conducting pertinent research and verification tasks.

PubMedVol. 48(5)
Shanghai Medical College of Fudan University (CN), Shanghai Power Equipment Research Institute (CN), The Medical Device (United Kingdom) (GB)
Quality and Safety in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

[Research on Test Method of Active Medical Device Preset Service Life Evaluation]. — Fei He, Weiming Wang · PubMed (2024) | TGRS Research Map | TGRS