Simplification of coronary continuous thermodilution

Abstract Background Continuous coronary thermodilution with saline permits the accurate measurement of volumetric blood flow (Q) and absolute microvascular resistance. However, this requires repositioning of the temperature sensor by the operator to measure the entry temperature of the saline infusate, denoted as Ti. Purpose We evaluated if Ti could be predicted based upon known parameters without compromising the accuracy of calculated Q. This would significantly simplify the technique and render it completely operator independent. Methods In a derivation cohort of 371 patients with Q measured both at rest and during hyperaemia, multivariate linear regression was used to derive an equation for the prediction of Ti. Agreement of standard Q (calculated with measured Ti) and simplified Q (calculated with predicted Ti) was assessed in a validation cohort of 120 patients that underwent repeat Q measurements. The accuracy of simplified Q was assessed in a second validation cohort of 23 patients with [15O]H2O positron emission tomography (PET)-derived Q measurements. Results Simplified Q exhibited strong agreement with standard Q (r=0.94 [95% CI 0.93-0.95], ICC 0.94 [95% CI 0.92-0.95], both p<0.001) (Figure 1). Simplified Q exhibited excellent agreement with PET-derived Q (r=0.86 [95% CI 0.75-0.92], ICC=0.84 [95% CI 0.72-0.91], both p<0.001) (Figure 2). Compared with standard Q, there was no statistically significant difference between correlation coefficients (p=0.29) or standard deviations of absolute differences with PET-derived Q (p=0.85). Conclusion Assessing volumetric coronary flow by continuous thermodilution with predicted Ti instead of measured Ti does not compromise its accuracy when compared to [15O]H2O PET. It significantly simplifies the technique and renders absolute coronary flow measurements completely operator independent.Figure 1.AgreementFigure 2.Accuracy

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1389
Citations
1
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplification of coronary continuous thermodilution

Carlos Collet, Paul Knaapen, Souhiela Fawaz, Henk Everaars et al.
1 citations
European Heart Journal
Cardiovascular Disease and Adiposity
0.40
article

Simplification of coronary continuous thermodilution

Carlos Collet, Paul Knaapen, Souhiela Fawaz, Henk Everaars, Danielle Keulards, Peter Damman, Bernard De Bruyne, Thomas R. Keeble, Michele Mattia Viscusi, Thabo Mahendiran
article en
1 citations

Abstract

Abstract Background Continuous coronary thermodilution with saline permits the accurate measurement of volumetric blood flow (Q) and absolute microvascular resistance. However, this requires repositioning of the temperature sensor by the operator to measure the entry temperature of the saline infusate, denoted as Ti. Purpose We evaluated if Ti could be predicted based upon known parameters without compromising the accuracy of calculated Q. This would significantly simplify the technique and render it completely operator independent. Methods In a derivation cohort of 371 patients with Q measured both at rest and during hyperaemia, multivariate linear regression was used to derive an equation for the prediction of Ti. Agreement of standard Q (calculated with measured Ti) and simplified Q (calculated with predicted Ti) was assessed in a validation cohort of 120 patients that underwent repeat Q measurements. The accuracy of simplified Q was assessed in a second validation cohort of 23 patients with [15O]H2O positron emission tomography (PET)-derived Q measurements. Results Simplified Q exhibited strong agreement with standard Q (r=0.94 [95% CI 0.93-0.95], ICC 0.94 [95% CI 0.92-0.95], both p<0.001) (Figure 1). Simplified Q exhibited excellent agreement with PET-derived Q (r=0.86 [95% CI 0.75-0.92], ICC=0.84 [95% CI 0.72-0.91], both p<0.001) (Figure 2). Compared with standard Q, there was no statistically significant difference between correlation coefficients (p=0.29) or standard deviations of absolute differences with PET-derived Q (p=0.85). Conclusion Assessing volumetric coronary flow by continuous thermodilution with predicted Ti instead of measured Ti does not compromise its accuracy when compared to [15O]H2O PET. It significantly simplifies the technique and renders absolute coronary flow measurements completely operator independent.Figure 1.AgreementFigure 2.Accuracy

European Heart JournalVol. 45(Supplement_1)
Radboud University Nijmegen (NL), Catharina Ziekenhuis (NL), Radboud University Medical Center (NL), Essex Cardiothoracic Centre (GB), Cardiovascular Research Center (BR), Vrije Universiteit Amsterdam (NL)
Good health and well-being
Openalex Percentile: Top 31%
Cardiovascular Disease and Adiposity
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.