Coronary sinus reducer device for the treatment of refractory angina: a single center experience

Abstract Introduction The coronary sinus Reducer emerged as a complementary therapy in patients with angina refractory to optimal medical therapy and not amenable to revascularization. Aim The aim of this study was to assess the safety and efficacy of the Reducer in a real-world cohort of patients presenting with refractory angina. Methods and population Twenty-six patients with refractory angina, objective evidence of myocardial ischemia attributable to the left coronary artery and deemed unsuitable for revascularization were treated with Reducer at a single center between April 2018 and January 2023. Safety endpoints were procedural success and complications. Efficacy endpoints, assessed at 6-month, were a reduction in Canadian Cardiovascular Society angina (CCS) class and a reduction in pharmacological antianginal therapy. Results Twenty-one (81%) patients had end-stage coronary artery disease without targets for further revascularization (13 had previous CABG ± PCI and 8 had only PCI) and 5 patients had microvascular disease without epicardial stenosis. All procedures were performed via right jugular vein. The mean procedure and fluoroscopy duration were 66±29 and 19±8 minutes. Procedural success was achieved in all patients, with no device related complications. There was one cardiac tamponade, promptly treated with pericardiocentesis. Regarding the efficacy endpoint, 21 patients (81%) had at least 1 grade reduction in CCS class, 13 patients (50%) had at least 2 class reductions, and 7 patients (28 %) became asymptomatic, with a mean reduction of CCS class of 1.4±0.9, from 2.6±0.5 to 1.2±0.9 (p=0.001) at 6-month follow-up. During this time frame, twelve patients (46%) withdrew or reduced the dose of at least one anti-anginal drug. The mean reduction of anti-anginal drugs was 0.54 ±0.86, from 3.5±1.02 to 2.9±1.07 (p=0.04). Conclusion In this real-world, single-center experience, implantation of Reducer was safe and associated with improvement of angina and reduction of anti-anginal drugs intake in patients with refractory angina unsuitable for revascularization.

Authors

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1407
Primary Topic
Pain Management and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coronary sinus reducer device for the treatment of refractory angina: a single center experience

Márcio Domingues, Rui Campante Teles, Luís Raposo, Manuel Almeida et al.
European Heart Journal
Pain Management and Treatment
article

Coronary sinus reducer device for the treatment of refractory angina: a single center experience

Márcio Domingues, Rui Campante Teles, Luís Raposo, Manuel Almeida, Joana Pereira, Renata Carvalho, João Brito, Sérgio Madeira
article en

Abstract

Abstract Introduction The coronary sinus Reducer emerged as a complementary therapy in patients with angina refractory to optimal medical therapy and not amenable to revascularization. Aim The aim of this study was to assess the safety and efficacy of the Reducer in a real-world cohort of patients presenting with refractory angina. Methods and population Twenty-six patients with refractory angina, objective evidence of myocardial ischemia attributable to the left coronary artery and deemed unsuitable for revascularization were treated with Reducer at a single center between April 2018 and January 2023. Safety endpoints were procedural success and complications. Efficacy endpoints, assessed at 6-month, were a reduction in Canadian Cardiovascular Society angina (CCS) class and a reduction in pharmacological antianginal therapy. Results Twenty-one (81%) patients had end-stage coronary artery disease without targets for further revascularization (13 had previous CABG ± PCI and 8 had only PCI) and 5 patients had microvascular disease without epicardial stenosis. All procedures were performed via right jugular vein. The mean procedure and fluoroscopy duration were 66±29 and 19±8 minutes. Procedural success was achieved in all patients, with no device related complications. There was one cardiac tamponade, promptly treated with pericardiocentesis. Regarding the efficacy endpoint, 21 patients (81%) had at least 1 grade reduction in CCS class, 13 patients (50%) had at least 2 class reductions, and 7 patients (28 %) became asymptomatic, with a mean reduction of CCS class of 1.4±0.9, from 2.6±0.5 to 1.2±0.9 (p=0.001) at 6-month follow-up. During this time frame, twelve patients (46%) withdrew or reduced the dose of at least one anti-anginal drug. The mean reduction of anti-anginal drugs was 0.54 ±0.86, from 3.5±1.02 to 2.9±1.07 (p=0.04). Conclusion In this real-world, single-center experience, implantation of Reducer was safe and associated with improvement of angina and reduction of anti-anginal drugs intake in patients with refractory angina unsuitable for revascularization.

European Heart JournalVol. 45(Supplement_1)
Openalex Percentile: Top 64%
Pain Management and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.