Diagnostic performance of semi-quantitative echocardiographic evaluation in patients with aortic regurgitation: implications for clinical practice

Abstract Background In current practice, screening for severe aortic regurgitation (AR) relies on qualitative and semi-quantitative echocardiographic parameters. No information is given on the diagnostic performance of each of these parameters. Objectives The purpose of this study was to investigate the diagnostic performance of semi-quantitative echocardiographic parameters in discriminating moderate from severe AR. Methods This single-center retrospective cohort study included 102 consecutive patients with chronic isolated moderate or severe AR. Patients were divided between severe and moderate AR using a combination of left ventricle (LV) dilatation, Proximal Isovelocity Surface Area (PISA) echocardiographic method and cardiovascular magnetic resonance (CMR). Receiver operator characteristic (ROC) curve analysis was performed to assess the diagnostic accuracy of vena contracta width (VC), pressure half-time (PHT) and diastolic flow reversal in descending aorta (DFR). Results Threshold value VC > 6mm provided a low sensitivity (40.4%) and an excellent 88.9% specificity for the diagnosis of severe AR. For PHT, the value < 200ms provided a poor sensitivity (2.0%) and an excellent 100% specificity. For DFR, the value ≥ 0.2m/s provided a low sensitivity (37.8%) and a good 78.6% specificity. These 3 parameters have a good positive predictive value (PPV) > 80% and a poor negative predictive value (NPV) < 40%. The area under the curve for the diagnosis of severe AR was 0.72, 0.72 and 0.59 for VC, PHT and DFR, respectively. Conclusion Our study demonstrates that the semi-quantitative parameters VC, PHT and DFR are highly specific but poorly sensitive for diagnosing severe chronic AR. They can rule in severe AR but in presence of intermediate values, they are insufficient to rule out severe AR.Venn diagramDiagnostic performance

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.139
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic performance of semi-quantitative echocardiographic evaluation in patients with aortic regurgitation: implications for clinical practice

Zohra Lamiral, Nikolai Paul Pace, Pablo Maureira, Olivier Huttin et al.
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Diagnostic performance of semi-quantitative echocardiographic evaluation in patients with aortic regurgitation: implications for clinical practice

Zohra Lamiral, Nikolai Paul Pace, Pablo Maureira, Olivier Huttin, Christine Selton‐Suty, M Dörr, Aurore Fraix, Frédéric Gauthier, Laura Filippetti
article en

Abstract

Abstract Background In current practice, screening for severe aortic regurgitation (AR) relies on qualitative and semi-quantitative echocardiographic parameters. No information is given on the diagnostic performance of each of these parameters. Objectives The purpose of this study was to investigate the diagnostic performance of semi-quantitative echocardiographic parameters in discriminating moderate from severe AR. Methods This single-center retrospective cohort study included 102 consecutive patients with chronic isolated moderate or severe AR. Patients were divided between severe and moderate AR using a combination of left ventricle (LV) dilatation, Proximal Isovelocity Surface Area (PISA) echocardiographic method and cardiovascular magnetic resonance (CMR). Receiver operator characteristic (ROC) curve analysis was performed to assess the diagnostic accuracy of vena contracta width (VC), pressure half-time (PHT) and diastolic flow reversal in descending aorta (DFR). Results Threshold value VC > 6mm provided a low sensitivity (40.4%) and an excellent 88.9% specificity for the diagnosis of severe AR. For PHT, the value < 200ms provided a poor sensitivity (2.0%) and an excellent 100% specificity. For DFR, the value ≥ 0.2m/s provided a low sensitivity (37.8%) and a good 78.6% specificity. These 3 parameters have a good positive predictive value (PPV) > 80% and a poor negative predictive value (NPV) < 40%. The area under the curve for the diagnosis of severe AR was 0.72, 0.72 and 0.59 for VC, PHT and DFR, respectively. Conclusion Our study demonstrates that the semi-quantitative parameters VC, PHT and DFR are highly specific but poorly sensitive for diagnosing severe chronic AR. They can rule in severe AR but in presence of intermediate values, they are insufficient to rule out severe AR.Venn diagramDiagnostic performance

European Heart JournalVol. 45(Supplement_1)
Centre Hospitalier Régional et Universitaire de Nancy (FR)
Openalex Percentile: Top 65%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.