Evaluation of a portable OSL/IRSL reader for radiation dose assessment of NaCl pellets – In situ individualised screening during R/N emergencies

Household salt, Sodium Chloride (NaCl), has been suggested as an appropriate material for retrospective and prospective optically stimulated luminescence (OSL) radiation dosimetry. The current paper investigates the potential application of NaCl pellets during a radiological and/or nuclear emergency, together with an existing portable reader, for application as a novel tool for in situ screening of individual doses in exposed populations. The evaluation of the portable reader's performance was assessed based on OSL and infra-red stimulated luminescence (IRSL) methods and the results were compared to two research readers, Risø TL/OSL (DA-20 and DA-15). For the studied absorbed dose range (0.63–487 mGy), it was found that five pellets are needed in the portable reader to achieve a similar OSL signal magnitude as using one pellet in the two research readers. The OSL results of the three readers show similar minimum detectable dose (MDD) values and similar linear trends for the obtained OSL dose response curves, within the studied dose range. The IRSL results show a lower IRSL signal for the portable reader, leading to higher MDD values compared to the stationary readers. The MDD can reach down to 2.3 and 47 μGy, respectively, for OSL and IRSL measurements of NaCl with the SUERC portable reader. Furthermore, sensitization tests show a dose dependent increase in the OSL and IRSL signals. In addition, the possibility of reading the same pellets more than once was confirmed through an advanced protocol, which combines multiple read-outs, and a time delay test. If a combination of OSL and IRSL measurements is applied, it is important to adjust the stimulation length if the first is OSL, while in the case that the first measurement is IRSL, the OSL signal is independent of the IRSL stimulation length. • OSL and IRSL studies on NaCl pellets made from household salt. • Benchmarking of a portable OSL/IRSL reader for in situ measurements. • Feasibility of mass-screening with NaCl pellets and a portable OSL/IRSL reader. • Development of an advanced protocol to allow re-assessment of the NaCl pellets.

Authors

Institutions

Publication Details

Journal
Radiation Measurements
Published
2024-10-28
DOI
https://doi.org/10.1016/j.radmeas.2024.107323
Citations
3
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a portable OSL/IRSL reader for radiation dose assessment of NaCl pellets – In situ individualised screening during R/N emergencies

Christopher Rääf, Maria Karampiperi, Christian Bernhardsson
3 citations
Radiation Measurements
Nuclear Physics and Applications
1.82
article

Evaluation of a portable OSL/IRSL reader for radiation dose assessment of NaCl pellets – In situ individualised screening during R/N emergencies

Christopher Rääf, Maria Karampiperi, Christian Bernhardsson
article en
3 citations

Abstract

Household salt, Sodium Chloride (NaCl), has been suggested as an appropriate material for retrospective and prospective optically stimulated luminescence (OSL) radiation dosimetry. The current paper investigates the potential application of NaCl pellets during a radiological and/or nuclear emergency, together with an existing portable reader, for application as a novel tool for in situ screening of individual doses in exposed populations. The evaluation of the portable reader's performance was assessed based on OSL and infra-red stimulated luminescence (IRSL) methods and the results were compared to two research readers, Risø TL/OSL (DA-20 and DA-15). For the studied absorbed dose range (0.63–487 mGy), it was found that five pellets are needed in the portable reader to achieve a similar OSL signal magnitude as using one pellet in the two research readers. The OSL results of the three readers show similar minimum detectable dose (MDD) values and similar linear trends for the obtained OSL dose response curves, within the studied dose range. The IRSL results show a lower IRSL signal for the portable reader, leading to higher MDD values compared to the stationary readers. The MDD can reach down to 2.3 and 47 μGy, respectively, for OSL and IRSL measurements of NaCl with the SUERC portable reader. Furthermore, sensitization tests show a dose dependent increase in the OSL and IRSL signals. In addition, the possibility of reading the same pellets more than once was confirmed through an advanced protocol, which combines multiple read-outs, and a time delay test. If a combination of OSL and IRSL measurements is applied, it is important to adjust the stimulation length if the first is OSL, while in the case that the first measurement is IRSL, the OSL signal is independent of the IRSL stimulation length. • OSL and IRSL studies on NaCl pellets made from household salt. • Benchmarking of a portable OSL/IRSL reader for in situ measurements. • Feasibility of mass-screening with NaCl pellets and a portable OSL/IRSL reader. • Development of an advanced protocol to allow re-assessment of the NaCl pellets.

Radiation MeasurementsVol. 179
Lund University (SE)
Openalex Percentile: Top 15%
Nuclear Physics and Applications
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.