Effects of Combined Cold Plasma and Organic Acid‐Based Sanitizer Treatments Against <i>Salmonella enterica</i> on Tomato Surfaces

ABSTRACT Incidence of foodborne illness due to bacterial contamination of fresh produce continue to exist despite continuous research on processing interventions to mitigate the problem. In this study, we combined atmospheric cold plasma treatments with an antimicrobial solution containing specific organic acids generally recognized as safe (GRAS) by the FDA and tested its antimicrobial efficacy against Salmonella enterica inoculated on tomato surfaces. Tomato surfaces were inoculated with at 5.6 log CFU/g of Salmonella by spotting 0.1 mL of 7 log CFU/ml Salmonella onto the tomato stem scars, and by dipping whole tomatoes into a solution of 7 log CFU/ml Salmonella for 3 min to achieve 4.1 log CFU/g. Antimicrobial efficacy of the organic acid‐based sanitizer + cold plasma treatments for 30, 60, 120, 180, and 360 s, were investigated, and significant bacterial inactivation was achieved above 120 s treatments. At 120 s, surviving populations of aerobic mesophilic bacteria recovered on the tomatoes surfaces averaged &lt; 2 logs/g while yeast and mold survival averaged &lt; 1 CFU/g. Treatment combination with this organic acid‐based sanitizer + cold plasma for 120 s resulted in a 4.9 log reduction of Salmonella on the stem scar area and a 3.9 log reduction on the smooth peel surface. Similarly, populations of aerobic mesophilic bacteria recovered on treated tomato surfaces averaged &lt; 0.3 log CFU/g. The results of this study indicate that combining an organic acid‐based sanitizer with cold plasma treatments for ≥ 120 s can inactivates significant populations of Salmonella to enhance the microbial safety of tomato surfaces designated for fresh‐cut salad.

Authors

Institutions

Publication Details

Journal
Journal of Food Safety
Published
2024-10-01
DOI
https://doi.org/10.1111/jfs.13172
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Combined Cold Plasma and Organic Acid‐Based Sanitizer Treatments Against Salmonella enterica on Tomato Surfaces

O. M. Olanya, Brendan A. Niemira, Dike O. Ukuku, Sudarsan Mukhopadhyay
Journal of Food Safety
Plasma Applications and Diagnostics
article

Effects of Combined Cold Plasma and Organic Acid‐Based Sanitizer Treatments Against Salmonella enterica on Tomato Surfaces

O. M. Olanya, Brendan A. Niemira, Dike O. Ukuku, Sudarsan Mukhopadhyay
article en

Abstract

ABSTRACT Incidence of foodborne illness due to bacterial contamination of fresh produce continue to exist despite continuous research on processing interventions to mitigate the problem. In this study, we combined atmospheric cold plasma treatments with an antimicrobial solution containing specific organic acids generally recognized as safe (GRAS) by the FDA and tested its antimicrobial efficacy against Salmonella enterica inoculated on tomato surfaces. Tomato surfaces were inoculated with at 5.6 log CFU/g of Salmonella by spotting 0.1 mL of 7 log CFU/ml Salmonella onto the tomato stem scars, and by dipping whole tomatoes into a solution of 7 log CFU/ml Salmonella for 3 min to achieve 4.1 log CFU/g. Antimicrobial efficacy of the organic acid‐based sanitizer + cold plasma treatments for 30, 60, 120, 180, and 360 s, were investigated, and significant bacterial inactivation was achieved above 120 s treatments. At 120 s, surviving populations of aerobic mesophilic bacteria recovered on the tomatoes surfaces averaged &lt; 2 logs/g while yeast and mold survival averaged &lt; 1 CFU/g. Treatment combination with this organic acid‐based sanitizer + cold plasma for 120 s resulted in a 4.9 log reduction of Salmonella on the stem scar area and a 3.9 log reduction on the smooth peel surface. Similarly, populations of aerobic mesophilic bacteria recovered on treated tomato surfaces averaged &lt; 0.3 log CFU/g. The results of this study indicate that combining an organic acid‐based sanitizer with cold plasma treatments for ≥ 120 s can inactivates significant populations of Salmonella to enhance the microbial safety of tomato surfaces designated for fresh‐cut salad.

Journal of Food SafetyVol. 44(5)
Agricultural Research Service (US), Eastern Regional Research Center (US)
U.S. Department of Agriculture, Agricultural Research Service
Openalex Percentile: Top 68%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.