Point of care ultrasound measurement of paralumbar caudal vena cava diameter and caudal vena cava to aortic ratio in hypovolemic dogs
Obtaining point of care ultrasound images for CVC:Ao measurement was feasible. With a marked decrease in intravascular volume, both CVC and Ao diameter decreased, resulting in an unchanged CVC:Ao. Despite changes in CVC and Ao diameters, these changes were not associated with measured changes in CO, emphasizing that CO is not a direct estimate of intravascular volume and is affected by many compensatory mechanisms. Additional studies are needed to determine the most accurate method for bedside measurement of intravascular volume status.
Authors
- Amanda A. Cavanagh
- Kristin M. Zersen (ORCID: https://orcid.org/0000-0003-0327-8537)
- Jenna H. Cardillo
Institutions
- Colorado State University (US)
Publication Details
- Journal
- Frontiers in Veterinary Science
- Published
- 2024-10-28
- DOI
- https://doi.org/10.3389/fvets.2024.1467043
- Citations
- 3
- Primary Topic
- Hemodynamic Monitoring and Therapy
- Type
- article
- Field-Weighted Citation Impact
- 1.72