First experimental verification of prompt gamma imaging with carbon ion irradiation

Prompt Gamma Imaging (PGI) is a promising technique for range verification in Particle Therapy. This technique was already tested in clinical environment with a knife-edge-collimator camera for proton treatments but remains relatively unexplored for Carbon Ion Radiation Therapy (CIRT). Previous FLUKA simulations suggested that PG profile shifts could be detected in CIRT with a precision of ∼ 4 mm ([Formula: see text]) for a particle statistic equal to [Formula: see text] C-ions using a 10 × 10 cm<sup>2</sup> camera. An experimental campaign was carried out at CNAO (Pavia, Italy) to verify these results, using a knife-edge-collimator camera prototype based on a 5 × 5 cm<sup>2</sup> pixelated LYSO crystal. PG profiles were measured irradiating a plastic phantom with a C-ion pencil beam at clinical energies and intensities, also moving the detector to extend the FOV to 13 × 5 cm<sup>2</sup>. The prototype detected Bragg-peak shifts with ∼ 4 mm precision for a statistic of [Formula: see text] C-ions ([Formula: see text] for the extended FOV), slightly larger than expected. Nevertheless, the detector demonstrated significant potential for verifying the precision in dose delivery following a treatment fraction, which remains fundamental in the clinical environment. For the first time to our knowledge, range verification based on PGI was applied to a C-ion beam at clinical energy and intensities.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-10-28
DOI
https://doi.org/10.1038/s41598-024-72870-6
Citations
11
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
4.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First experimental verification of prompt gamma imaging with carbon ion irradiation

Marco Carminati, Marco Donetti, Aicha Bourkadi Idrissi, F. Camera et al.
11 citations
Scientific Reports
Radiation Therapy and Dosimetry
4.61
article

First experimental verification of prompt gamma imaging with carbon ion irradiation

Marco Carminati, Marco Donetti, Aicha Bourkadi Idrissi, F. Camera, G. Borghi, Carlo Ettore Fiorini, Simone Savazzi, Marco Pullia, Christian Riboldi, Anita Caracciolo
article en
11 citations

Abstract

Prompt Gamma Imaging (PGI) is a promising technique for range verification in Particle Therapy. This technique was already tested in clinical environment with a knife-edge-collimator camera for proton treatments but remains relatively unexplored for Carbon Ion Radiation Therapy (CIRT). Previous FLUKA simulations suggested that PG profile shifts could be detected in CIRT with a precision of ∼ 4 mm ([Formula: see text]) for a particle statistic equal to [Formula: see text] C-ions using a 10 × 10 cm<sup>2</sup> camera. An experimental campaign was carried out at CNAO (Pavia, Italy) to verify these results, using a knife-edge-collimator camera prototype based on a 5 × 5 cm<sup>2</sup> pixelated LYSO crystal. PG profiles were measured irradiating a plastic phantom with a C-ion pencil beam at clinical energies and intensities, also moving the detector to extend the FOV to 13 × 5 cm<sup>2</sup>. The prototype detected Bragg-peak shifts with ∼ 4 mm precision for a statistic of [Formula: see text] C-ions ([Formula: see text] for the extended FOV), slightly larger than expected. Nevertheless, the detector demonstrated significant potential for verifying the precision in dose delivery following a treatment fraction, which remains fundamental in the clinical environment. For the first time to our knowledge, range verification based on PGI was applied to a C-ion beam at clinical energy and intensities.

Scientific ReportsVol. 14(1)
University of Milan (IT), National Center for Oncological Hadrontherapy (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Milano (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 4%
Radiation Therapy and Dosimetry
4.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.