Effect of ethanol addition on enhancing the cooling performance improvement of spray system

The widespread application of spray technology has significantly improved outdoor environmental thermal comfort. However, the spray system is unable to fulfill special comfort requirements. Utilizing mechanical ventilation and control systems effectively enhances the cooling performance of spray systems; however, those approaches are associated with elevated costs and maintenance complexities. The combination of ethanol and water has been demonstrated to produce a lower surface tension and a higher latent heat of evaporation, a property that contributes to the heat transfer efficiency and evaporation rate of the droplets. Considering the convenience and cost-effectiveness of adding ethanol as an additive, it emerges as the optimal choice. To evaluate the effectiveness of ethanol on the evaporative cooling performance of the spray system, a comparative study was conducted, comparing the cooling performances of different concentrations of ethanol with a spray system without ethanol addition. Five operating conditions were designed, including a no-spray case, a non-additive case, a 0.5 % ethanol concentration case, a 1.0 % ethanol concentration case, and a 1.5 % ethanol concentration case. The results demonstrated that adding ethanol effectively enhanced the cooling performance of the spray system. At 1.7m above ground level (0.4m away from the nozzle), compared to the non-additive case without ethanol, the 0.5 % ethanol concentration case, 1.0 % ethanol concentration case, and 1.5 % ethanol concentration case further reduced the temperature by 0.95 °C, 1.64 °C, and 2.27 °C. Moreover, the relative humidity grew by 3.57 %, 9.25 %, and 13.5 %, respectively. Adding ethanol significantly enhanced the evaporative cooling effect of the spray system, with the optimal concentration observed at 1.5 %. The results demonstrate that enhancing the evaporative cooling efficacy of a spray system by introducing ethanol into the spray medium represents a viable strategy and improve urban thermal environment in summer. Furthermore, this study aims to examine the impact of droplet evaporation on relative humidity, establishing a foundation for future enhancements aimed at addressing the issue of over-humidification in spray systems.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-10-28
DOI
https://doi.org/10.1016/j.csite.2024.105357
Citations
4
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of ethanol addition on enhancing the cooling performance improvement of spray system

Xi Meng, Yi Gao, Liming Ge
4 citations
Case Studies in Thermal Engineering
Urban Heat Island Mitigation
0.82
article

Effect of ethanol addition on enhancing the cooling performance improvement of spray system

Xi Meng, Yi Gao, Liming Ge
article en
4 citations

Abstract

The widespread application of spray technology has significantly improved outdoor environmental thermal comfort. However, the spray system is unable to fulfill special comfort requirements. Utilizing mechanical ventilation and control systems effectively enhances the cooling performance of spray systems; however, those approaches are associated with elevated costs and maintenance complexities. The combination of ethanol and water has been demonstrated to produce a lower surface tension and a higher latent heat of evaporation, a property that contributes to the heat transfer efficiency and evaporation rate of the droplets. Considering the convenience and cost-effectiveness of adding ethanol as an additive, it emerges as the optimal choice. To evaluate the effectiveness of ethanol on the evaporative cooling performance of the spray system, a comparative study was conducted, comparing the cooling performances of different concentrations of ethanol with a spray system without ethanol addition. Five operating conditions were designed, including a no-spray case, a non-additive case, a 0.5 % ethanol concentration case, a 1.0 % ethanol concentration case, and a 1.5 % ethanol concentration case. The results demonstrated that adding ethanol effectively enhanced the cooling performance of the spray system. At 1.7m above ground level (0.4m away from the nozzle), compared to the non-additive case without ethanol, the 0.5 % ethanol concentration case, 1.0 % ethanol concentration case, and 1.5 % ethanol concentration case further reduced the temperature by 0.95 °C, 1.64 °C, and 2.27 °C. Moreover, the relative humidity grew by 3.57 %, 9.25 %, and 13.5 %, respectively. Adding ethanol significantly enhanced the evaporative cooling effect of the spray system, with the optimal concentration observed at 1.5 %. The results demonstrate that enhancing the evaporative cooling efficacy of a spray system by introducing ethanol into the spray medium represents a viable strategy and improve urban thermal environment in summer. Furthermore, this study aims to examine the impact of droplet evaporation on relative humidity, establishing a foundation for future enhancements aimed at addressing the issue of over-humidification in spray systems.

Case Studies in Thermal EngineeringVol. 63
Qingdao University of Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Shandong Province
Affordable and clean energy
Openalex Percentile: Top 30%
Urban Heat Island Mitigation
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.