Investigation of the Effect of Variations in the Puncture Site of the Arteriovenous Fistula on Access Blood Flow Measurement by Ultrasound Dilution Method

Background: In assessing vascular access (VA) function, access blood flow (Qa) using the UDM method is more common. However, because of the wide variety of vascular branches in arteriovenous fistula (AVF), Qa measurement may be difficult depending on the puncture position, considering the measurement principle of the ultrasound dilution method (UDM). In this study, we investigated the effect of puncture variation on Qa measurement in AVF. The results were also compared with Qa by ultrasonic Doppler method (Qa (DU)). Methods: The 337 dialysis patients with AVF were divided into 3 groups (Figure1) (Group A:117 patients without a vascular branch between A and V at the puncture site, Group B:112 patients with a vascular branch, and Group C:98 patients with a separate vessel). Qa was measured during dialysis using HD03 dialysis monitor. Qa (DU) was also measured in the brachial artery by the ultrasonic Doppler method. This study protocol was conducted in accordance with the Principle of the Declaration of Helsinki, and was approved by the Ethics Committee of Osaka Metropolitan University (approval No.2021-243). Results: As a result, Qa measurement errors in group A were 28/117 (23.9%), in group B 39/122 (32.0%), and in group C 96/98 (98.0%). Qa (DU) was measurable in all groups in this case. Moreover, group A showed a significant positive correlation between Qa and Qa (DU) (R=0.712, P<0.0001), group B showed a significant positive correlation between Qa and Qa (DU) (R=0.565, P<0.0001), and group C showed no correlation between Qa and Qa (DU) due to many measurement errors of Qa. Conclusion: Based on these results, we believe that the choice of puncture position is important for Qa measurement by UDM, and that if recirculation is not observed or if a vascular bifurcation is present, the puncture position is not suitable for Qa measurement. On the other hand, Qa(DU) could be measured in all cases, which may be a better method of measuring access flow in AVF.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2024-10-01
DOI
https://doi.org/10.1681/asn.20240afmck86
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Effect of Variations in the Puncture Site of the Arteriovenous Fistula on Access Blood Flow Measurement by Ultrasound Dilution Method

Junji Uchida, Yoshiaki Takemoto, Tomoaki Iwai, Toshihide Naganuma et al.
Journal of the American Society of Nephrology
Central Venous Catheters and Hemodialysis
article

Investigation of the Effect of Variations in the Puncture Site of the Arteriovenous Fistula on Access Blood Flow Measurement by Ultrasound Dilution Method

Junji Uchida, Yoshiaki Takemoto, Tomoaki Iwai, Toshihide Naganuma, K.H. Shin
article en

Abstract

Background: In assessing vascular access (VA) function, access blood flow (Qa) using the UDM method is more common. However, because of the wide variety of vascular branches in arteriovenous fistula (AVF), Qa measurement may be difficult depending on the puncture position, considering the measurement principle of the ultrasound dilution method (UDM). In this study, we investigated the effect of puncture variation on Qa measurement in AVF. The results were also compared with Qa by ultrasonic Doppler method (Qa (DU)). Methods: The 337 dialysis patients with AVF were divided into 3 groups (Figure1) (Group A:117 patients without a vascular branch between A and V at the puncture site, Group B:112 patients with a vascular branch, and Group C:98 patients with a separate vessel). Qa was measured during dialysis using HD03 dialysis monitor. Qa (DU) was also measured in the brachial artery by the ultrasonic Doppler method. This study protocol was conducted in accordance with the Principle of the Declaration of Helsinki, and was approved by the Ethics Committee of Osaka Metropolitan University (approval No.2021-243). Results: As a result, Qa measurement errors in group A were 28/117 (23.9%), in group B 39/122 (32.0%), and in group C 96/98 (98.0%). Qa (DU) was measurable in all groups in this case. Moreover, group A showed a significant positive correlation between Qa and Qa (DU) (R=0.712, P<0.0001), group B showed a significant positive correlation between Qa and Qa (DU) (R=0.565, P<0.0001), and group C showed no correlation between Qa and Qa (DU) due to many measurement errors of Qa. Conclusion: Based on these results, we believe that the choice of puncture position is important for Qa measurement by UDM, and that if recirculation is not observed or if a vascular bifurcation is present, the puncture position is not suitable for Qa measurement. On the other hand, Qa(DU) could be measured in all cases, which may be a better method of measuring access flow in AVF.

Journal of the American Society of NephrologyVol. 35(10S)
Osaka Metropolitan University (JP)
Good health and well-being
Openalex Percentile: Top 67%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.