Automated self-adjustment of array probe with a robotic ultrasonic test system

Ultrasonic testing of objects with complex geometries often requires the use of a robotic arm to position the probe perpendicular to the local surface. Using immersion makes it possible to test these objects with standard ultrasonic linear array probes. Here, the probe positions and orientations provided by the robot are used for merging the locally acquired image data into a 3D-reconstruction. The quality of this reconstruction is highly dependent on the alignment of the position of the physical probe with the position used in the digital model. For common industrial tools, the tool center point (TCP) is usually acquired using geometric features of the tools. However, for ultrasonic arrays in immersion, there is a water standoff between the probe and the test object, therefore the TCP is in free space in front of the array and cannot be acquired with the common method. To overcome this challenge, we propose a method that allows the robotic ultrasonic system to automatically self-adjust the position and orientation of the ultrasonic probe using a test block made of steel with defined geometric features as a target for referencing. For each of the six degrees of freedom, a scan and adjustment routine are established using the data based on the actual ultrasound characteristics of the probe. Given a coarse pre-definition of the tool position and the known target test block, minimal human interaction is required to supervise the adjustment method, leading to higher quality reconstructions than with manual adjustment.

Authors

Publication Details

Journal
e-Journal of Nondestructive Testing
Published
2024-10-28
DOI
https://doi.org/10.58286/30309
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated self-adjustment of array probe with a robotic ultrasonic test system

Christian Hassenstein, Thomas Heckel, Jonas Wassermann, Philipp Daniel Hirsch
e-Journal of Nondestructive Testing
Engineering Applied Research
article

Automated self-adjustment of array probe with a robotic ultrasonic test system

Christian Hassenstein, Thomas Heckel, Jonas Wassermann, Philipp Daniel Hirsch
article en

Abstract

Ultrasonic testing of objects with complex geometries often requires the use of a robotic arm to position the probe perpendicular to the local surface. Using immersion makes it possible to test these objects with standard ultrasonic linear array probes. Here, the probe positions and orientations provided by the robot are used for merging the locally acquired image data into a 3D-reconstruction. The quality of this reconstruction is highly dependent on the alignment of the position of the physical probe with the position used in the digital model. For common industrial tools, the tool center point (TCP) is usually acquired using geometric features of the tools. However, for ultrasonic arrays in immersion, there is a water standoff between the probe and the test object, therefore the TCP is in free space in front of the array and cannot be acquired with the common method. To overcome this challenge, we propose a method that allows the robotic ultrasonic system to automatically self-adjust the position and orientation of the ultrasonic probe using a test block made of steel with defined geometric features as a target for referencing. For each of the six degrees of freedom, a scan and adjustment routine are established using the data based on the actual ultrasound characteristics of the probe. Given a coarse pre-definition of the tool position and the known target test block, minimal human interaction is required to supervise the adjustment method, leading to higher quality reconstructions than with manual adjustment.

e-Journal of Nondestructive TestingVol. 29(11)
European Regional Development Fund
Openalex Percentile: Top 78%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.